Sökning: onr:"swepub:oai:lup.lub.lu.se:2317d1e5-d83d-4927-bf3d-0f2f9a332e7d" >
Övertändning, backd...
Övertändning, backdraft och brandgasexplosion sett ur räddningstjänstens perspektiv
-
- Bengtsson, Lars-Göran (författare)
- Lund University,Lunds universitet,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
-
(creator_code:org_t)
- 1999
- Svenska.
- Relaterad länk:
-
https://portal.resea... (primary) (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- This report presents a detailed description of the phenomena flashover, backdraft and smoke gas explosion. The physical and chemical processes which are involved in these phenomena are thoroughly discussed. The report also describes a number of compartment fire scenarios which are believed to be the most common scenarios occurring in Sweden. The description is based on a number of full- scale experiments which were carried out within the project. At the end of the report, possible warning signs of a potential flashover and backdraft are discussed. In the appendices, a number of models used to predict flashover are evaluated, using data from small scale experiments carried out within the project.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Annan samhällsbyggnadsteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Other Civil Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)