Sökning: onr:"swepub:oai:lup.lub.lu.se:26489ac9-92aa-4875-885a-ac50ce83d876" >
Effects of the cool...
Effects of the cooling configurations layout near the first-stage vane leading edge on the endwall cooling and phantom cooling of the vane suction side surface
-
- Du, Kun (författare)
- Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,Xi'an Jiaotong University
-
- Li, Jun (författare)
- Collaborative Innovation Center of Advanced Aero-Engine,Xi'an Jiaotong University
-
- Sunden, Bengt (författare)
- Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
-
(creator_code:org_t)
- Elsevier BV, 2018
- 2018
- Engelska 14 s.
-
Ingår i: International Journal of Heat and Mass Transfer. - : Elsevier BV. - 0017-9310. ; 123, s. 1021-1034
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Increasing the turbine inlet temperature can enhance the thermal efficiency of a gas turbine. Therefore, modern gas turbines operate at a relatively high level of temperature and endure heavy thermal load. It is important to ensure the modern gas turbine works at a high performance and safe condition. Advanced cooling techniques are implemented in the gas turbine system. In the current study, effects of the cooling configurations layout near the first-stage vane leading edge on the endwall cooling and phantom cooling of the vane suction side surface were numerically investigated. Three-dimensional (3D) Reynolds-averaged Navier-Stokes (RANS) equations combined with the shear stress transport (SST) k-ω turbulence model were solved to perform the simulations on basis of validation by comparing the experimental data and computational results. The results indicate that the layout of the cooling configurations has a significant influence on the endwall cooling, but a limited effect on the phantom cooling of the suction side surface and the aerodynamic performance. For each type, the endwall cooling and phantom cooling of the suction side surface are enhanced with the increase of the blowing ratio (M) of the leading edge coolant injection. Meanwhile, the thermodynamic loss is gradually enhanced. Overall, the Type B which has a partly blocked upstream slot achieves the best performance in terms of the coolant mass flowrate, endwall cooling, phantom cooling performance of the suction side surface and the aerodynamic performance at M=1.0.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
Nyckelord
- Cooling configurations layout
- Endwall cooling
- Numerical simulation
- Phantom cooling
Publikations- och innehållstyp