Sökning: onr:"swepub:oai:lup.lub.lu.se:287b58fb-4e9f-4d28-923f-35a1b83fbb43" >
Core Lab Adjudicati...
Core Lab Adjudication of the ACURATE neo2 Hemodynamic Performance Using Computed-Tomography-Corrected Left Ventricular Outflow Tract Area
-
- Elkoumy, Ahmed (författare)
- Galway University Hospital
-
- Rück, Andreas (författare)
- Karolinska Institutet,Karolinska University Hospital
-
- Kim, Won Keun (författare)
- Max Planck Institute for Heart and Lung Research
-
visa fler...
-
- Abdel-Wahab, Mohamed (författare)
- Leipzig University
-
- Abdelshafy, Mahmoud (författare)
- Galway University Hospital
-
- De Backer, Ole (författare)
- Copenhagen University Hospital
-
- Elzomor, Hesham (författare)
- Galway University Hospital
-
- Hengstenberg, Christian (författare)
- Medical University of Vienna
-
- Mohamed, Sameh K. (författare)
- Galway University Hospital
-
- Saleh, Nawzad (författare)
- Karolinska Institutet,Karolinska University Hospital
-
- Arsang-Jang, Shahram (författare)
- Galway University Hospital
-
- Bjursten, Henrik (författare)
- Lund University,Lunds universitet,Skonsammare hjärtkirurgi,Forskargrupper vid Lunds universitet,Less invasive cardiac surgery,Lund University Research Groups,Skåne University Hospital
-
- Simpkin, Andrew (författare)
- National University of Ireland Galway
-
- Meduri, Christopher U. (författare)
- Karolinska University Hospital
-
- Soliman, Osama (författare)
- Galway University Hospital
-
visa färre...
-
(creator_code:org_t)
- 2022-10-17
- 2022
- Engelska.
-
Ingår i: Journal of Clinical Medicine. - : MDPI AG. - 2077-0383. ; 11:20, s. 1-12
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.3...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- (1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE neo2. The LVOT area and its dependent Doppler-derived parameters, including effective orifice area (EOA) and stroke volume (SV), in addition to their indexed values, were calculated from post-TAVI 2D-TTE. In addition, the 3D-LVOT area from pre-procedural MDCT scans was obtained and used to calculate corrected Doppler-derived parameters. The incidence rates of prosthesis patient mismatch (PPM) were compared between the 2D-TTE and MDCT-based methods (3) Results: The main results show that the 2D-TTE measured LVOT is significantly smaller than 3D-MDCT (350.4 ± 62.04 mm2 vs. 405.22 ± 81.32 mm2) (95% Credible interval (CrI) of differences: −55.15, −36.09), which resulted in smaller EOA (2.25 ± 0.59 vs. 2.58 ± 0.63 cm2) (Beta = −0.642 (95%CrI of differences: −0.85, −0.43), and lower SV (73.88 ± 21.41 vs. 84.47 ± 22.66 mL), (Beta = −7.29 (95% CrI: −14.45, −0.14)), respectively. PPM incidence appears more frequent with 2D-TTE- than 3D-MDCT-corrected measurements (based on the EOAi) 8.52% vs. 2.32%, respectively. In addition, significant differences regarding the EOA among the three valve sizes (S, M and L) were seen only with the MDCT, but not on 2D-TTE. (4) Conclusions: The corrected continuity equation by combining the 3D-LVOT area from MDCT with the TTE Doppler parameters might provide a more accurate assessment of hemodynamic parameters and PPM diagnosis in patients treated with TAVI. The ACURATE neo2 THV has a large EOA and low incidence of PPM using the 3D-corrected LVOT area than on 2D-TTE. These findings need further confirmation on long-term follow-up and in other studies.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- ACURATE neo2
- aortic stenosis
- computed tomography
- echocardiography
- hemodynamic performance
- left ventricular outflow tract
- prosthesis patient mismatch
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Elkoumy, Ahmed
-
Rück, Andreas
-
Kim, Won Keun
-
Abdel-Wahab, Moh ...
-
Abdelshafy, Mahm ...
-
De Backer, Ole
-
visa fler...
-
Elzomor, Hesham
-
Hengstenberg, Ch ...
-
Mohamed, Sameh K ...
-
Saleh, Nawzad
-
Arsang-Jang, Sha ...
-
Bjursten, Henrik
-
Simpkin, Andrew
-
Meduri, Christop ...
-
Soliman, Osama
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Kardiologi
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
Journal of Clini ...
- Av lärosätet
-
Lunds universitet
-
Karolinska Institutet