Sökning: onr:"swepub:oai:lup.lub.lu.se:2b1986ce-25df-4cb9-a10e-293b1d270e17" >
Mobility determinat...
Mobility determination of lead isotopes in glass for retrospective radon measurements
-
Laitinen, Mikko (författare)
-
Riihimaki, Iiro (författare)
-
- Ekman, Jörgen (författare)
- Malmö högskola,Teknik och samhälle (TS)
-
visa fler...
-
Sagari, A. R. Ananda (författare)
-
Karlsson, Lennart B. (författare)
-
Sangyuenyongpipat, Somjai (författare)
-
Gorelick, Sergey (författare)
-
Kettunen, Heikki (författare)
-
Penttila, Heikki (författare)
-
- Hellborg, Ragnar (författare)
- Lund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
Sajavaara, Timo (författare)
-
Helgesson, Johan (författare)
-
Whitlow, Harry J. (författare)
-
visa färre...
-
(creator_code:org_t)
- Oxford University Press (OUP), 2008
- 2008
- Engelska.
-
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 131:3, s. 212-216
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://jyx.jyu.fi/b...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- In retrospective radon measurements, the 22-y half life of Pb-210 is used as an advantage. Pb-210 is often considered to be relatively immobile in glass after alpha recoil implanted by Rn-222 progenies. The diffusion of Pb-210 could, however, lead to uncertain wrong retrospective radon exposure estimations if Pb-210 is mobile and can escape from glass, or lost as a result of cleaning-induced surface modification. This diffusion was studied by a radiotracer technique, where Pb-209 was used as a tracer in a glass matrix for which the elemental composition is known. Using the ion guide isotope separator on-line technique, the Pb-209 atoms were implanted into the glass with an energy of 39 keV. The diffusion profiles and the diffusion coefficients were determined after annealing at 470-620 degrees C and serial sectioning by ion sputtering. In addition, the effect of surface cleaning on diffusion was tested. From the Arrhenius fit, the activation enthalpy (H) was determined, which is equal to 3.2 +/- 0.2 eV, and also the pre-exponential factor D-0, in the order of 20 m(2)s(-1). This result confirms the assumption that over a time period of 50 y Pb-209 (and Pb-210) is effectively immobile in the glass. The boundary condition obtained from the measurements had the characteristic of a sink, implying loss of Pb-209 in the topmost surface at high temperatures.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Laitinen, Mikko
-
Riihimaki, Iiro
-
Ekman, Jörgen
-
Sagari, A. R. An ...
-
Karlsson, Lennar ...
-
Sangyuenyongpipa ...
-
visa fler...
-
Gorelick, Sergey
-
Kettunen, Heikki
-
Penttila, Heikki
-
Hellborg, Ragnar
-
Sajavaara, Timo
-
Helgesson, Johan
-
Whitlow, Harry J ...
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
Radiation Protec ...
- Av lärosätet
-
Lunds universitet
-
Malmö universitet