A comparison of serum and EDTA plasma in the measurement of glutamic acid decarboxylase autoantibodies (GADA) and autoantibodies to islet antigen-2 (IA-2A) using the RSR radioimmunoassay (RIA) and enzyme linked immunosorbent assay (ELISA) kits.
-
Rahmati, Kobra (författare)
-
- Lernmark, Åke (författare)
- Lund University,Lunds universitet,Celiaki och diabetes,Forskargrupper vid Lunds universitet,Celiac Disease and Diabetes Unit,Lund University Research Groups
-
- Becker, Charlotte (författare)
- Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
-
visa fler...
-
- Foltyn Zadura, Anna (författare)
- Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
-
Larsson, Karin (författare)
-
- Ivarsson, Sten (författare)
- Lund University,Lunds universitet,Pediatrisk endokrinologi,Forskargrupper vid Lunds universitet,Paediatric Endocrinology,Lund University Research Groups
-
- Törn, Carina (författare)
- Lund University,Lunds universitet,Celiaki och diabetes,Forskargrupper vid Lunds universitet,Celiac Disease and Diabetes Unit,Lund University Research Groups
-
visa färre...
-
(creator_code:org_t)
- 2008
- 2008
- Engelska.
-
Ingår i: Clinical Laboratory. - 1433-6510. ; 54:7-8, s. 227-235
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- BACKGROUND: Glutamic acid decarboxylase antibodies (GADA) and tyrosine phosphatase antibodies (islet antigen-2 antibodies; IA-2A) are used in clinical practise to identify type 1 diabetes. METHODS: GADA and IA-2A were measured with RSR-ELISA kits in samples from 76 newly diagnosed type 1 diabetic children and 120 healthy controls. The aim was to evaluate performance of RSR-ELISA kits for GADA and IA-2A when serum and Ca2+ treated plasma were used. RESULTS: GADA achieved high area under the curve (AUC) both for serum 0.95 (95% CI 0.90-0.99) and for Ca2+ treated plasma 0.95 (95% CI 0.91-0.99). At specificity 98%, sensitivity was 84% for serum and 87% for Ca2+ treated plasma. IA-2A achieved AUC 0.92 (95% CI 0.87-0.97) for serum and 0.94 (95% CI 0.90-0.98) for Ca2+ treated plasma. Using the lowest standard (15 WHO-Units/ml) as cut-off, specificity for serum was 100% and for Ca2+ treated plasma 99% with sensitivity 74% in both cases. Sensitivity was higher in ELISA compared to RIA (74%; p = 0.0080) for GADA measurement and similar for ELISA and RIA IA-2A measurements (76%; p = 0.50). CONCLUSION: Both RSR-ELISAs, GADA and IA-2A showed excellent performance for serum as well as for Ca2+ treated plasma.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)