SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:4bc1f4aa-786e-4a24-9b41-f7fbdea5a3a6"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:4bc1f4aa-786e-4a24-9b41-f7fbdea5a3a6" > Accuracy of duplex ...

Accuracy of duplex sonography before carotid endarterectomy--a comparison with angiography

Hansen, F (författare)
Bergqvist, D (författare)
Lindblad, Bengt (författare)
Lund University,Lunds universitet,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Vascular Diseases - Clinical Research,Lund University Research Groups
visa fler...
Lindh, Mats (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Mätzsch, Thomas (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Department of Clinical Sciences, Malmö,Faculty of Medicine,Vascular Diseases - Clinical Research,Lund University Research Groups
Lanne, T (författare)
visa färre...
 (creator_code:org_t)
1996
1996
Engelska.
Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 12:3, s. 331-336
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVES: The aim of this prospective study was to contribute to the evaluation of the reliability of Duplex sonography (DS) before carotid endarterectomy (CEA). DESIGN: The study was performed prospectively in a university hospital setting. METHODS: Eighty-one consecutive patients aged 49-83 years were examined with DS and carotid angiography (CAG) before CEA. The results of the DS were judged as either confident, or CAG was assessed to be necessary preoperatively. The results from the DS and the CAG were then compared. RESULTS: DS was judged as confident in 148 of the 162 arteries examined. In none of these 148 arteries did CAG change patient management in any way, and the agreement between DS and CAG was good. In the remaining 14 arteries CAG was judged necessary, in 11 arteries because DS assessed the internal carotid artery (ICA) as occluded, which was confirmed by CAG in 10 arteries. In three arteries the reason was poor quality of the DS, however these three arteries were correctly assessed as severely diseased. CONCLUSIONS: This study confirms that DS alone is sufficient in the preoperative evaluation before CEA, provided that CAG is performed whenever DS shows occlusion of the ICA, or when the quality of the DS is poor.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Carotid artery
Duplex sonography
Carotid angiography
Carotid artery stenosis
Doppler

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hansen, F
Bergqvist, D
Lindblad, Bengt
Lindh, Mats
Mätzsch, Thomas
Lanne, T
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
European Journal ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy