SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:4bfe6035-7f9e-42d6-bbd3-5d933f5c0a85"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:4bfe6035-7f9e-42d6-bbd3-5d933f5c0a85" > Improved Time-Frequ...

Improved Time-Frequency Analysis of Atrial Fibrillation Signals Using Spectral Modeling

Corino, Valentina D. A. (författare)
Mainardi, Luca T. (författare)
Stridh, Martin (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Sörnmo, Leif (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2008
2008
Engelska.
Ingår i: IEEE Transactions on Biomedical Engineering. - 1558-2531. ; 55:12, s. 2723-2730
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In patients with atrial fibrillation (AF), the fibrillatory frequency trend and the time-dependent spectral characteristics can be investigated using a spectral profile technique. The spectral profile is updated by fitting each short-time spectrum. The aim of this study is to develop model-based means for stricter control on the update of the spectral profile. A spectral model defined by a superposition of Gaussian functions is suggested for describing the fundamental and harmonics of the atrial waves during AF, thereby accounting for basic characteristics of the typical AF spectrum. The model parameters are obtained from weighted least squares fitting of the model to the observed spectrum. The method was tested on simulated signals as well as on 48 ECG recordings from 15 patients with persistent AF. Using simulated signals, we assessed the accuracy in terms of magnitude and width or the spectral peaks. For SNR = 0 dB, the maximum normalized error was less than 0.2 when estimating magnitude of both the fundamental and the harmonics, whereas it was less than 0.15 for the fundamental and 0.7 for the harmonics with respect to the estimation of the width. We observed a marked Improvement while tracking the main fibrillatory frequency as the error was reduced by more than 50% In comparison with the original method. Analyzing ECGs, reliable spectral profiles were obtained In all recordings, even In those cases (5/48) that were not well characterized by the original method.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

fibrillatory frequency
Gaussian
time-frequency analysis
functions
Atrial fibrillation (AF)
ECG

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Corino, Valentin ...
Mainardi, Luca T ...
Stridh, Martin
Sörnmo, Leif
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Artiklar i publikationen
IEEE Transaction ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy