Molecularly imprinted polymer films for reflectometric interference spectroscopic sensors

Belmont, Anne-Sophie (författare)
Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Jaeger, Stefanie (författare)
Knopp, Dietmar (författare)
visa fler...
Niessner, Reinhard (författare)
Gauglitz, Guenter (författare)
Haupt, Karsten (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 22:12, s. 3267-3272
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Reflectometric interference spectroscopic measurements were performed on molecularly imprinted polymer (MIP) films with the herbicide atrazine as the template molecule. A conventional imprinting protocol was used relying on non-covalent interactions between the functional monomers and the template. The MIPs were deposited on glass transducers by two different methods: spin-coating followed by in situ polymerization of thin films of monomers containing a sacrificial polymeric porogen, and autoassembly of MIP nanoparticles with the aid of an associative linear polymer. Reproducible results were obtained upon measurements of atrazine solutions in toluene with both films. Atrazine concentrations as low as 1.7 pprn could be detected with the autoassembled particle film. No or very little analyte adsorption was observed onto non-imprinted control films made by spin-coating and by particle assembly, respectively. We believe that these MIP layers in combination with the general reflectrometric transduction scheme could be a versatile sensing tool for the detection of environmentally important and other analytes. (c) 2007 Elsevier B.V. All rights reserved.

Ämnesord

NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Nyckelord

molecularly imprinted polymer
synthetic receptor
chemical sensor
reflectometric interference spectroscopy
thin film

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy