SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:54c386f8-b08b-403a-a887-84c4031e53dd"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:54c386f8-b08b-403a-a887-84c4031e53dd" > Modeling the influe...

Modeling the influence of TR and excitation flip angle on the magnetization transfer ratio (MTR) in human brain obtained from 3D spoiled gradient echo MRI

Helms, Gunther (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Dathe, Henning (författare)
Dechent, Peter (författare)
 (creator_code:org_t)
2010-05-20
2010
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 64:1, s. 177-185
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Attempts to optimize the magnetization transfer ratio (MTR) obtained from spoiled gradient echo MRI have focused on the properties of the magnetization transfer pulse. In particular, continuous-wave models do not explicitly account for the effects of excitation and relaxation on the MTR. In this work, these were modeled by an approximation of free relaxation between the radiofrequency pulses and of an instantaneous saturation event describing the magnetization transfer pulse. An algebraic approximation of the signal equation can be obtained for short pulse repetition time and small flip angles. This greatly facilitated the mathematical treatment and understanding of the MTR. The influence of inhomogeneous radiofrequency fields could be readily incorporated. The model was verified on the human brain in vivo at 3 T by variation of flip angle and pulse repetition time. The corresponding range in MTR was similar to that observed by a 4-fold increase of magnetization transfer pulse power. Choice of short pulse repetition time and larger flip angles improved the MTR contrast and reduced the influence of radiofrequency inhomogeneity. Optimal contrast is obtained around an MTR of 50%, and noise progression is reduced when a high reference signal is obtained.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Helms, Gunther
Dathe, Henning
Dechent, Peter
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk bildbe ...
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy