Energy-efficient flat-tube heat exchangers for indirectly cooled display cabinets

Haglund Stignor, Caroline (författare)
SP Sveriges Tekniska Forskningsinstitut AB,Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
Sundén, Bengt (författare)
Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,Chalmers tekniska högskola,Chalmers University of Technology
Fahlén, Per, 1947 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
Elsevier BV, 2009
2009
Engelska.
Ingår i: International Journal of Refrigeration. - : Elsevier BV. - 0140-7007. ; 32:6, s. 1460-1471
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Different designs of flat-tube heat exchangers with plain fins have been evaluated theoretically in a parameter study in order to evaluate their performance potential in indirectly cooled display cabinets. Two different types of flat-tube heat exchangers were considered; one with serpentine fins and one with continuous plate fins. Both flat-tube heat exchanger types were adapted to the laminar flow regime on the liquid as well as on the air side. The performance of the two heat exchanger types had previously been verified experimentally under dehumidifying conditions. The results from this parameter study show that considerable savings in the required electric drive power to compressors, pumps and fans can be obtained in comparison with the traditional cooling coil. The savings may be up to 15%. In addition, the required temperature difference for the flat-tube heat exchangers is so small that frost-free operation is possible, which would result in even larger savings. (C) 2009 Elsevier Ltd and IIR. All rights reserved.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Energy efficiency
Calculation
Geometry
Finned tube
Tube
Heat exchanger
Display cabinet
indirectly cooled display cabinets

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy