Sökning: onr:"swepub:oai:lup.lub.lu.se:68d833c9-fc78-4ffc-9f70-12046ebe74f7" >
Comparison of hemod...
Comparison of hemodialysis using a medium cutoff dialyzer versus hemodiafiltration : A controlled cross-over study
-
- Lindgren, Anna (författare)
- Lund University,Lunds universitet,Internmedicin - epidemiologi,Forskargrupper vid Lunds universitet,Internal Medicine - Epidemiology,Lund University Research Groups,Skåne University Hospital
-
- Fjellstedt, Erik (författare)
- Lund University,Lunds universitet,Internmedicin - epidemiologi,Forskargrupper vid Lunds universitet,Internal Medicine - Epidemiology,Lund University Research Groups,Skåne University Hospital
-
- Christensson, Anders (författare)
- Lund University,Lunds universitet,Internmedicin - epidemiologi,Forskargrupper vid Lunds universitet,Internal Medicine - Epidemiology,Lund University Research Groups,Skåne University Hospital
-
(creator_code:org_t)
- 2020
- 2020
- Engelska 8 s.
-
Ingår i: International Journal of Nephrology and Renovascular Disease. - 1178-7058. ; 13, s. 273-280
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.2...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose: Conventional hemodialysis (HD) treatment has an acceptable removal of small uremic molecules, but so-called middle molecules in the range of 0.5-60 kDa are poorly cleared with HD compared to a native kidney, which may contribute to morbidity in the dialysis population. Hemodiafiltration (HDF) has a better removal of middle molecules compared to HD but is technically demanding and requires well-functioning dialysis access. The newly introduced medium cutoff (MCO) filters have been developed to enhance middle molecule clearance in HD-mode. The aim of this study was to compare reduction ratios (RRs) of molecules with different molecular weights (0.06-150 kDa) during dialysis with MCO dialyzer (used in HD-mode) compared to online-hemodiafiltration (ol-HDF) treatment with a conventional high-flux dialyzer. Patients and Methods: This is a prospective controlled single-center cross-over study, including 16 patients in Malmo, Sweden. All patients had ongoing post-dilution ol-HDF treatment before the study. The study compared reduction ratios of small-, middle-, and large-sized molecules during a single 4h dialysis treatment with post-dilution ol-HDF (Polyflux 210H) to a 4h dialysis treatment with MCO dialyzer (Theranova 500) in HDmode. Between treatments, the patients had a washout period of at least two weeks of their ordinary HDF treatment to reach their ordinary steady state. Results: Ol-HDF had significantly higher RR for cystatin C (13 kDa), compared to MCO (RR 68.1 vs 65.8, p=0.003), during a 4h dialysis treatment (mean convection volume of 24.5 L for HDF, and mean Qb of 324 mL/min for HDF and 323 mL/min for MCO). There was no significant difference in the RR for other middle molecules, or for smaller or larger molecules. Conclusion: Overall, the RRs were comparable for ol-HDF and MCO-HD. There was a slightly higher RR of cystatin C (a small middle molecule) for HDF compared to MCO but no difference in other measured molecules.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Urology and Nephrology (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap -- Folkhälsovetenskap, global hälsa, socialmedicin och epidemiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences -- Public Health, Global Health, Social Medicine and Epidemiology (hsv//eng)
Nyckelord
- Chronic hemodialysis
- Dialysis
- Hemodiafiltration
- Hemodialysis
- MCO
- Uremic toxins
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas