SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:6ca978f9-200c-4b6e-94a0-98149617d164"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:6ca978f9-200c-4b6e-94a0-98149617d164" > Comparison of two e...

Comparison of two extraction methods for the determination of selective serotonin reuptake inhibitors in sewage sludge by hollow fiber liquid-phase microextraction

Sagrista, Ester (författare)
Manuel Cortes, Jose (författare)
Larsson, Estelle (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Salvado, Victoria (författare)
Hidalgo, Manuela (författare)
Jönsson, Jan Åke (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2012-07-02
2012
Engelska.
Ingår i: Journal of Separation Science. - : Wiley. - 1615-9314 .- 1615-9306. ; 35:18, s. 2460-2468
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper presents two procedures for the determination of four selective serotonin reuptake inhibitors (citalopram, paroxetine, fluoxetine, and sertraline) and one metabolite (norfluoxetine) in sewage sludge utilizing three-phase hollow fiber liquid-phase microextraction (HF-LPME). First, direct HF-LPME was used for extraction, clean-up, and preconcentration. The pharmaceuticals were extracted from slurry samples into an organic phase and then back-extracted into an aqueous phase in the lumen of the hollow fiber. Second, a procedure combining pressurized hot water extraction and HF-LPME for clean-up and preconcentration was developed for the same analytes and matrix. The extracts were subsequently analyzed by liquid chromatographymass spectrometry. For direct HF-LPME, limits of detection were between 1 and 12 ng g-1 (dry weight) and the relative standard deviation (RSD) values were 312%. For the second method, limits of detection were approximately 6 ng g-1 for all the compounds and RSD values were 812%. The methods were validated by comparison of results for the same samples. Sewage sludge from a Swedish wastewater treatment plant was analyzed by both methods; average concentrations were similar for citalopram, paroxetine, and fluoxetine with values of approximately 530, 40, and 200 ng g-1, respectively.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Hollow fiber liquid-phase microextraction
Pressurized hot water
extraction
Selective serotonin reuptake inhibitors
Sewage sludge

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy