Sökning: onr:"swepub:oai:lup.lub.lu.se:743ac15a-dd00-4641-992c-fe907bd3785a" > Mass overloading in...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02426naa a2200289 4500 | |
001 | oai:lup.lub.lu.se:743ac15a-dd00-4641-992c-fe907bd3785a | |
003 | SwePub | |
008 | 160401s2003 | |||||||||||000 ||eng| | |
024 | 7 | a https://lup.lub.lu.se/record/1327172 URI |
024 | 7 | a https://doi.org/10.1016/S0021-9673(03)01145-22 DOI |
040 | a (SwePub)lu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a art2 swepub-publicationtype |
072 | 7 | a ref2 swepub-contenttype |
100 | 1 | a Arfvidsson, Ceciliau Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)tak-car |
245 | 1 0 | a Mass overloading in the flow field-flow fractionation channel studied by the behaviour of the ultra-large wheat protein glutein. |
264 | 1 | c 2003 |
520 | a Flow field-flow fractionation (FFF) has previously been used in successful fractionation and characterisation of the ultra-large wheat protein glutenin. The many parameters, which may influence the retention behaviour, especially when analysing extremely high-molecular-mass samples such as glutenin, are here reported. Size determination from the sample retention time, using FFF theory, will as a result have a very low accuracy. The need for direct molecular mass determination, such as by light scattering, in combination with FFF, in order to do accurate size measurements of glutenin is pointed out as well as the importance to minimise the overloading. | |
650 | 7 | a NATURVETENSKAPx Kemix Analytisk kemi0 (SwePub)104012 hsv//swe |
650 | 7 | a NATURAL SCIENCESx Chemical Sciencesx Analytical Chemistry0 (SwePub)104012 hsv//eng |
700 | 1 | a Wahlund, Karl-Gustavu Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)tak-kgw |
710 | 2 | a Centrum för analys och syntesb Kemiska institutionen4 org |
773 | 0 | t Journal of Chromatography Ag 1011:1-2, s. 99-109q 1011:1-2<99-109x 0021-9673 |
856 | 4 | u http://dx.doi.org/10.1016/S0021-9673(03)01145-2y FULLTEXT |
856 | 4 8 | u https://lup.lub.lu.se/record/132717 |
856 | 4 8 | u https://doi.org/10.1016/S0021-9673(03)01145-2 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy