Sökning: onr:"swepub:oai:lup.lub.lu.se:791a9af4-2a40-42a4-8a44-99a6a06edbc8" >
A database of multi...
A database of multi-channel intramuscular electromyogram signals during isometric hand muscles contractions
-
- Malesevic, Nebojsa (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Björkman, Anders (författare)
- Lund University,Lunds universitet,Handkirurgi, Malmö,Forskargrupper vid Lunds universitet,WCMM- Wallenberg center för molekylär medicinsk forskning,Medicinska fakulteten,Hand Surgery, Malmö,Lund University Research Groups,WCMM-Wallenberg Centre for Molecular Medicine,Faculty of Medicine,Skåne University Hospital
-
- Andersson, Gert S. (författare)
- Lund University,Lunds universitet,Klinisk neurofysiologi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Neurophysiology,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
-
visa fler...
-
- Matran-Fernandez, Ana (författare)
- University of Essex
-
- Citi, Luca (författare)
- University of Essex
-
- Cipriani, Christian (författare)
- Sant'Anna School of Advanced Studies
-
- Antfolk, Christian (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 2020-01-08
- 2020
- Engelska.
-
Ingår i: Scientific Data. - : Springer Science and Business Media LLC. - 2052-4463. ; 7:1
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://www.nature.c...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Hand movement is controlled by a large number of muscles acting on multiple joints in the hand and forearm. In a forearm amputee the control of a hand prosthesis is traditionally depending on electromyography from the remaining forearm muscles. Technical improvements have made it possible to safely and routinely implant electrodes inside the muscles and record high-quality signals from individual muscles. In this study, we present a database of intramuscular EMG signals recorded with fine-wire electrodes alongside recordings of hand forces in an isometric setup and with the addition of spike-sorted metadata. Six forearm muscles were recorded from twelve able-bodied subjects and nine forearm muscles from two subjects. The fully automated recording protocol, based on command cues, comprised a variety of hand movements, including some requiring slowly increasing/decreasing force. The recorded data can be used to develop and test algorithms for control of a prosthetic hand. Assessment of the signals was done in both quantitative and qualitative manners.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)