SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:7cd16412-cd78-49fd-8772-9740a059ddbf"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:7cd16412-cd78-49fd-8772-9740a059ddbf" > Non-axisymmetric En...

Non-axisymmetric Endwall film cooling characteristics considering the influences of cylindrical holes and laidback fan-shaped holes

Du, Kun (författare)
Northwestern Polytechnic University
Jia, Yihao (författare)
Northwestern Polytechnic University
Liu, Cunliang (författare)
Northwestern Polytechnic University
visa fler...
Sunden, Bengt (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,LTH profilområde: Nanovetenskap och halvledarteknologi,LTH profilområden,LU profilområde: Ljus och material,Lunds universitets profilområden,Other operations, LTH,Faculty of Engineering, LTH,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: Nanoscience and Semiconductor Technology,LTH Profile areas,Faculty of Engineering, LTH,LU Profile Area: Light and Materials,Lund University Profile areas
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: International Journal of Heat and Mass Transfer. - 0017-9310. ; 225
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Flow fields near the turbine vane endwall are complicated due to the endwall cross flows. The use of a non-axisymmetric endwall is regarded as an efficient technique to reduce the lateral pressure difference, decreasing the endwall cross flow. Numerical analysis was performed to determine how the non-axisymmetric endwall affected the vortex structure and heat transfer level. The cooling performance was investigated with cylindrical and laidback fan-shaped holes (7–7–7), which were arranged in rows aligned in the axial direction. The results showed that the non-axisymmetric endwall could significantly reduce the circumferential pressure difference and suppress the growth of the passage vortex, and the area-averaged heat transfer coefficient was reduced by 3.34%. The outlet area of the film hole was altered by the non-axisymmetric endwall, and the over-cooled regions may have appeared as a result of the excessive area increase. The influence of the non-axisymmetric endwall was concentrated at 0.4 < Z/Cax < 1.0 for the cylindrical hole. With the increase in M, the film cooling effectiveness of the non-axisymmetric endwall attained a higher level than that of the flat endwall. For the laidback fan-shaped hole, the effect of the non-axisymmetric endwall was confined within 0.25 < Z/Cax < 1.0. The half-period trigonometric function of the non-axisymmetric endwall (HTFN) achieved the optimal cooling performance for three blowing ratios. However, the periodic trigonometric function of the non-axisymmetric endwall (PTFN) only outperformed the flat endwall when M= 1.5.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Nyckelord

Aerodynamic characteristics
Film cooling
Laidback Fan-shaped Hole
Non-axisymmetric endwall

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Du, Kun
Jia, Yihao
Liu, Cunliang
Sunden, Bengt
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Strömningsmekani ...
Artiklar i publikationen
International Jo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy