Measurement of radiation distribution on the absorber in an asymmetric CPC collector
-
- Adsten, M (författare)
- Uppsala universitet,Materialvetenskap
-
- Hellström, Bengt (författare)
- Lund University,Lunds universitet,Avdelningen för Energi och byggnadsdesign,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Energy and Building Design,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
-
Karlsson, B (författare)
-
(creator_code:org_t)
- Elsevier BV, 2004
- 2004
- Engelska.
-
Ingår i: Solar Energy. - : Elsevier BV. - 0038-092X .- 1471-1257. ; 76:1-3, s. 199-206
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- A method to estimate the annual collected energy and the annual average optical efficiency factor is suggested. The radiation distribution on the absorber of an asymmetric CPC collector with a flat bi-facial absorber is measured for three different absorber mounting angles using a photo diode. The annual optical efficiency factors and a relative measure of the annual collected energy are determined for collectors with the absorber fin thickness 0.5 and 1 mm, and for a collector with a teflon convection suppression film mounted around the absorber. With the local optical efficiency factors and the annual incident solar energy distribution considered, the analysis indicates that the energy gain for a mounting angle of 20 is higher than for a collector with 65 absorber mounting angle. The annual collected energy is increased with 6-8% if the absorber fin thickness is increased from 0.5 to 1 mm. The annual average optical efficiency factor is relatively independent of the absorber mounting angle. It was found to be 0.87-0.88 for a collector with a 0.5 mm thick absorber fin and 0.92 for a collector with a 1 mm thick absorber fin or for a collector with 0.5 mm thick absorber fin with a teflon convection suppression film added. The low annual average optical efficiency factor is not caused by the uneven irradiance distribution but by the relatively high U-L-values. (C) 2003 Elsevier Ltd. All rights reserved.