Suture-TOOL : A suturing device for swift and standardized abdominal aponeurosis closure

Börner, Gabriel (författare)
Helsingborg Hospital
Edelhamre, Marcus (författare)
Helsingborg Hospital
Rogmark, Peder (författare)
Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups,Skåne University Hospital
visa fler...
Montgomery, Agneta (författare)
Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
Elsevier BV, 2022
2022
Engelska.
Ingår i: Surgery in Practice and Science. - : Elsevier BV. - 2666-2620. ; 11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction: Surgeons can reduce incisional hernia formation by adhering to standardized techniques for incisional wound closure. This is often neglected by the time a long operation is to be ended and can lead to the risk of developing an incisional hernia or a wound rupture. To address this issue, a suturing machine (Suture-TOOL) was developed for swift and standardized abdominal closure. The aim was to compare the user safety, speed, and suturing quality between Suture-TOOL and manual Needle-Driver suturing. Method: Fifteen surgeons who were specialists in surgery, urology, and gynaecology as well as surgical trainees were invited. The Suture-TOOL was presented to the surgeons who read the instructions for use before starting the test. Each surgeon closed nine 15 cm-long incisions in a human body model; six with Suture-TOOL and three with the Needle-Driver technique. Gloves were examined for puncture damage. Endpoints were suture-length/wound-length (SL/WL)-ratio, closure time, number of stitches, learning curve, and glove puncture rate. A VAS-evaluation concerning different Suture-Tool user impressions was completed. Results: A SL/WL-ratio ≥4 was 98% for Suture-TOOL versus 69% for Needle-Driver (p < 0.001). Suture time was shorter for Suture-TOOL (p < 0.001). Wound stitch count was higher for Needle-Driver (p = 0.013). The median SL/WL-ratio was similar between groups. The learning curve plateaued after three closures using Suture-TOOL. Two glove punctures were detected—all in the Needle-Driver group. Suture-TOOL received high VAS scores for all measured functionalities. Conclusion: Suture-TOOL is a promising device for clinical use. It is safe, easy, and fast resulting in a high-quality suture lines with a short learning curve and a high functionality ranking.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Abdominal wall closure
Mechanical device
Standardization
Suture device
Suture technique
Wound closure technique

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Börner, Gabriel
Edelhamre, Marcu ...
Rogmark, Peder
Montgomery, Agne ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Surgery in Pract ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy