Sökning: onr:"swepub:oai:lup.lub.lu.se:904874b9-d914-48c8-874c-3c0ea574da86" >
Elimination of S100...
Elimination of S100B and renal function after cardiac surgery
-
- Bjursten, Henrik (författare)
- Lund University,Lunds universitet,Thoraxkirurgi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Thoracic Surgery,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Johnsson, Per (författare)
-
- Höglund, Peter (författare)
- Lund University,Lunds universitet,Avdelningen för klinisk kemi och farmakologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Clinical Chemistry and Pharmacology,Department of Laboratory Medicine,Faculty of Medicine
-
visa fler...
-
- Alling, Christer (författare)
- Lund University,Lunds universitet,Avdelningen för klinisk kemi och farmakologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Clinical Chemistry and Pharmacology,Department of Laboratory Medicine,Faculty of Medicine
-
- Blomquist, Sten (författare)
- Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2000
- 2000
- Engelska.
-
Ingår i: Journal of Cardiothoracic and Vascular Anesthesia. - : Elsevier BV. - 1532-8422 .- 1053-0770. ; 14:6, s. 698-701
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- OBJECTIVES: To determine the biologic half-life of the S100B protein and to investigate if the elimination of S100B depends on glomerular filtration rate (GFR). DESIGN: Prospective human study. SETTING: University hospital. PARTICIPANTS: Sixteen patients who underwent cardiac surgery with cardiopulmonary bypass. INTERVENTIONS: Shed mediastinal blood (autotransfusion) was returned to the patients postoperatively and used to study the kinetics of S100B. Iohexol was infused simultaneously to estimate GFR. S100B was measured at 0, 20, 40, 60, and 180 minutes after infusion. Iohexol was measured at 180 and 240 minutes after infusion. MEASUREMENTS AND MAIN RESULTS: S100B followed first-order kinetics, and the biologic half-life for S100B was determined to be 25.3 +/- 5.1 minutes. GFR was determined to be 63.8 +/- 34.4 mL/min. No correlation was found between GFR and S100B half-life. CONCLUSIONS: The elimination of S100B after cardiac surgery is faster than reported earlier and not affected by a moderate decrease in GFR. This finding is important when evaluating S100B levels after cardiac surgery.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas