Sensitivity enhance...
Sensitivity enhancement and fringe reduction in tunable diode laser spectroscopy using hemispherical diffusers
-
- Lundin, Patrik (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
- Karlsson, Marcus (författare)
- Lund University
-
- Mei, Liang (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
visa fler...
-
- Larsson, Jim (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Förbränningsfysik,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH,Combustion Physics,Faculty of Engineering, LTH
-
- Somesfalean, Gabriel (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
- Svanberg, Sune (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH,South China Normal University
-
visa färre...
-
(creator_code:org_t)
- AIP Publishing, 2017
- 2017
- Engelska.
-
Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 88:5
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The use of diffuse, highly reflective optical components, in particular, a hemispherical BaSO4 diffuser, at the point of light injection into non-transparent or turbid media was evaluated as a means to increase the measurement sensitivity of spectroscopic absorption measurements. By performing the light injection from, e.g., an optical fiber through a component designed to make the light diffuse and to reflect (and thereby re-inject) light scattered from the sample, the total amount of light delivered into the sample is increased. Further, the occurrence of possible interference fringes is strongly reduced.