Model-based Assessment of f-Wave Signal Quality in Patients with Atrial Fibrillation
-
- Henriksson, Mikael (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Petrenas, Andrius (författare)
- Kaunas University of Technology
-
- Marozas, Vaidotas (författare)
- Kaunas University of Technology
-
visa fler...
-
- Sandberg, Frida (författare)
- Lund University,Lunds universitet,Electrocardiology Research Group - CIEL,Forskargrupper vid Lunds universitet,Lund University Research Groups
-
- Sornmo, Leif (författare)
- Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 2018
- 2018
- Engelska.
-
Ingår i: IEEE Transactions on Biomedical Engineering. - 1558-2531. ; 65:11, s. 2600-2611
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective: The detection and analysis of atrial fibrillation (AF) in the ECG is greatly influenced by signal quality. The present study proposes and evaluates a model-based f-wave signal quality index (SQI), denoted S, for use in the QRST-cancelled ECG signal. Methods: S is computed using a harmonic f-wave model, allowing for variation in frequency and amplitude. The properties of S are evaluated on both f-waves and P-waves using 378 12-lead ECGs, 1875 single-lead ECGs, and simulated signals. Results: S decreases monotonically when noise is added to f-wave signals, even for noise which overlaps spectrally with f-waves. Moreover, S is shown to be closely associated with the accuracy of AF frequency estimation, where S>0.3 implies accurate estimation. When S is used as a measure of f-wave presence, AF detection performance improves: the sensitivity increases from 97.0% to 98.1% and the specificity increases from 97.4% to 97.8% when compared to the reference detector. Conclusion: The proposed SQI represents a novel approach to assessing f-wave signal quality, as well as to determining whether f-waves are present. Significance: The use of S improves the detection of AF and benefits the analysis of noisy ECGs.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
Nyckelord
- AF detection
- Atrial fibrillation (AF)
- Computational modeling
- Detectors
- ECG
- Electrocardiography
- Estimation
- f-wave modeling
- Frequency estimation
- Harmonic analysis
- Indexes
- signal quality index (SQI)