Sökning: onr:"swepub:oai:lup.lub.lu.se:a617318e-a21f-49d9-ad57-3a3996c542e0" >
Application of supe...
Application of supercritical carbon dioxide for the extraction of alkylresorcinols from rye bran
-
- da Cruz Francisco, José (författare)
- Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
- Danielsson, Bengt (författare)
- Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
Kozubek, A (författare)
-
visa fler...
-
- Dey, Estera (författare)
- Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2005
- 2005
- Engelska.
-
Ingår i: Journal of Supercritical Fluids. - : Elsevier BV. - 0896-8446. ; 35:3, s. 220-226
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The use of supercritical CO, (SC-CO2) for extracting alkylresorcinols from rye bran was investigated. For pure SC-CO2, 35 MPa and 55 degrees C were used. SC-CO2 with 10% ethanol or methanol as co-solvents was tested at four pressure levels (8, 15, 30 and 35 MPa) and two temperatures (40 and 55 degrees C). Experiments were conducted at a constant SC-CO2 flow of 5 g/min for 2 h. For comparative purposes acetone at ambient temperature and pressure was also used for extraction. The best extractions were achieved when SC-CO2 was used with co-solvents. At 55 degrees C and 15-30 MPa, the use Of SC-CO2 with co-solvents has yielded from 8 to 80% (w/w) more extracted product than acetone. Yield of extracts was proportional to pressure (when above 30 MPa) and temperature. The results suggest that cleaner bran extracts can be obtained by using pure SC-CO2 followed by the addition of co-solvents. There is no clear advantage of using either methanol or ethanol. (c) 2005 Elsevier B.V. All rights reserved.
Ämnesord
- NATURVETENSKAP -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
- NATURAL SCIENCES -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas