On-line Heart Rate Monitoring Using the Extra-corporeal Pressure Sensors of a Dialysis Machine
-
- Holmer, Mattias (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Grigonyte, Egle (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Olde, Bo (författare)
-
visa fler...
-
Sternby, Jan (författare)
-
- Segelmark, Mårten (författare)
- Lund University,Lunds universitet,Njurmedicin,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Nephrology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Solem, Kristian (författare)
- Lund University,Lunds universitet,Institutioner vid LTH,Lunds Tekniska Högskola,Departments at LTH,Faculty of Engineering, LTH
-
- Sörnmo, Leif (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 2012
- 2012
- Engelska.
-
Ingår i: Biomedical engineering – 2012 : proceedings of international conference. - 2029-3380.
- Relaterad länk:
-
https://lup.lub.lu.s...
Abstract
Ämnesord
Stäng
- Heart rate can be extracted from the extracorporeal venous pressure signal of a dialysis machine. The results are of comparable accuracy and reliability to the ones obtained by the PPG reference signal from a pulse oximeter. Difficulties that occur during heart rate estimation were determined, and some can be overcome by a slight adjustment of blood flow rate. The described techniques, after being implemented into the dialysis machines, would help to improve current hemodialysis safety throughout the treatment by on-line monitoring of the cardiac activity.