Sökning: onr:"swepub:oai:lup.lub.lu.se:b3ff387f-bdfe-41ff-b42e-363a7d793736" >
Picodroplet-deposit...
Picodroplet-deposition of enzymes on functionalized self-assembled monolayers as a basis for miniaturized multi-sensor structures
-
Mosbach, M (författare)
-
Zimmermann, H. (författare)
-
- Laurell, Thomas (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
visa fler...
-
Nilsson, J. (författare)
-
- Csöregi, Elisabeth (författare)
- Lund University,Lunds universitet,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
Schuhmann, W. (författare)
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2001
- 2001
- Engelska.
-
Ingår i: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 16:9-12, s. 827-837
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- We are reporting on a novel approach for structured immobilisation of enzymes on gold surfaces modified with monolayers of functionalised alkylthiols. The formation of enzyme spots is achieved by shooting very small volumes of an appropriate enzyme solution (down to 100 pl) onto a thiol-monolayer modified gold surface using a micro-dispenser. Formation of enzyme patterns is obtained by moving the micro-dispenser relative to the modified gold surface using a micro-positioning device. Enzyme spots with typical lateral dimensions of 100 ml are obtained, but also, more complex structures, e.g. lines or meander structures, can be achieved by multiple droplets dispensed during the concomitant movement of the micro-dispenser. The first enzyme layer on top of the functionalised thiol-monolayer is subsequently covalently immobilised using either carbodiimide activation of carboxilic headgroups at the enzyme or via already introduced activated ester functions at the monolayer. Immobilised enzyme activities of glucose oxidase and lactate oxidase patterns have been characterised by means of scanning electrochemical microscopy. The product of the enzyme-catalysed reaction, H2O2, is detected with an micro-electrode in the presence of either or both substrates, glucose and lactate, leading to a visualisation of the corresponding enzyme pattern and the lateral enzymatic activity. (C) 2001 Elsevier Science B.V. All rights reserved.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Industriell bioteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Industrial Biotechnology (hsv//eng)
Nyckelord
- microdispenser
- microstructure
- enzymes
- scanning electrochemical
- microscopy
- SCANNING ELECTROCHEMICAL MICROSCOPY
- MODIFIED GOLD ELECTRODE
- CAPILLARY-ELECTROPHORESIS
- AMPEROMETRIC BIOSENSORS
- GLUCOSE-OXIDASE
- REDOX ENZYMES
- SURFACES
- IMMOBILIZATION
- POLYPYRROLE
- FABRICATION
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas