SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:be25a243-0352-4253-be79-488f16364b1e"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:be25a243-0352-4253-be79-488f16364b1e" > Soft x-ray undulato...

Soft x-ray undulator beam line 1411 at MAX-II for gases, liquids and solid samples

Bässler, M. (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Forsell, J. O. (författare)
Uppsala University
Björneholm, O. (författare)
Uppsala University
visa fler...
Feifel, R. (författare)
Uppsala University
Jurvansuu, M. (författare)
University of Oulu
Aksela, S. (författare)
University of Oulu
Sundin, S. (författare)
Uppsala University
Ristinmaa Sorensen, Stacey (författare)
University of Tartu
Nyholm, R. (författare)
University of Tartu
Ausmees, A. (författare)
University of Tartu
Svensson, S. (författare)
Uppsala University
visa färre...
 (creator_code:org_t)
Elsevier BV, 1999
1999
Engelska 5 s.
Ingår i: Journal of Electron Spectroscopy and Related Phenomena. - : Elsevier BV. - 0368-2048. ; 101-103, s. 953-957
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We report on the build-up of the new undulator beam line 1411 at the third-generation synchrotron radiation facility MAX II in Lund, Sweden. This beam line is based on an upgraded version of the modified SX700-monochromator and the end station which were installed previously at beam line 51 at MAX I. The end station is equipped with a rotatable Scienta hemispherical electron-analyser making angle-resolved high resolution electron spectroscopy possible for various kinds of samples. The beam line performance will be considerably improved on MAX II due to a new undulator and the superior light source properties, e.g. the small vertical electron beam size. Undulator spectra have been measured and estimates of the photon flux at the experiment and the expected energy resolution are presented. The parameters for a new refocusing mirror were defined by ray tracing using the beam waist of the undulator. The beam line length was extended by 1 m to offer additional space for exchangeable experimental chambers.

Nyckelord

Electron spectroscopy
Soft X-rays
Synchrotron
Undulator beam line

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy