Reducing cooling demands in a hot dry climate: A simulation study for non-insulated passive cool roof thermal performance in residential buildings

Dabaieh, Marwa (författare)
Lund University,Lunds universitet,Institutionen för arkitektur och byggd miljö,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Architecture and Built Environment,Departments at LTH,Faculty of Engineering, LTH,Architecture and Built Environment, LTH, Lund University, Lund, Sweden
Wanas, Omar (författare)
Architecture Department, Faculty of Fine Arts, Helwan University, Helwan, Egypt
Hegazy, Mohamed Amer (författare)
Transsolar Energietechnik GmbH, Stuttgart, Germany
visa fler...
Johansson, Erik (författare)
Lund University,Lunds universitet,Institutionen för arkitektur och byggd miljö,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Architecture and Built Environment,Departments at LTH,Faculty of Engineering, LTH,Architecture and Built Environment, LTH, Lund University, Lund, Sweden
visa färre...
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska 11 s.
Ingår i: Energy and Buildings. - : Elsevier BV. - 1872-6178 .- 0378-7788. ; 89, s. 142-152
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In hot dry climates, it is estimated that almost half the urban peak load of energy consumption is used to satisfy air-conditioning cooling demands in summer time. Since the urbanization rate in developing countries – like the case in Egypt – is rising rapidly, the pressure placed on energy resources to satisfy inhabitants’ indoor comfort requirements is consequently increasing too. This paper introduces passive cool roof as a means of reducing energy cooling loads for satisfying human comfort requirements in a hot climate. A designed algorithmic hybrid matrix was used to simulate 37 roof design probabilities alternating roof shape, roof material and construction. The result of using a vault roof with high albedo coating shows a fall of 53% in discomfort hours and saves 826 kW h during the summer season compared to the base case of the conventional non insulated flat roof in a typical Cairo residential buildings. It is recommended that the selected cool roof solution be combined with natural ventilation to increase the indoor thermal comfort, and with passive heating strategies to compensate the increase in heating hours. The application is intended for low cost residential buildings in a hot dry climate.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)
HUMANIORA  -- Konst -- Arkitektur (hsv//swe)
HUMANITIES  -- Arts -- Architecture (hsv//eng)

Nyckelord

Passive cooling
Cool roof
Thermal performance
Energy efficient roofs
Energy loads
Cooling demand
Hot dry climate
Passive coolingCool roofThermal performanceEnergy efficient roofsEnergy loadsCooling demandHot dry climate

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Dabaieh, Marwa
Wanas, Omar
Hegazy, Mohamed ...
Johansson, Erik
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
HUMANIORA
HUMANIORA
och Konst
och Arkitektur
Artiklar i publikationen
Energy and Build ...
Av lärosätet
Lunds universitet
Malmö universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy