Identification of femoral head center of bipolar hemiarthroplasy in radiostereometric analysis with elementary geometrical shape models.
-
- Tsukanaka, Masako (författare)
- Oslo university hospital
-
- Röhrl, Stephan M (författare)
- Oslo university hospital
-
- von Schewelov, Thord (författare)
- Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
-
visa fler...
-
- Nordsletten, Lars (författare)
- Oslo university hospital
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2016
- 2016
- Engelska.
-
Ingår i: Journal of Biomechanics. - : Elsevier BV. - 1873-2380 .- 0021-9290. ; 49:3, s. 469-473
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Elementary geometrical shape (EGS) models are useful in radiostereometric analysis (RSA) on hip stems because tantalum markers attached to the stems can be omitted. In order to create an EGS model of a femoral stem, the center of the femoral head has to be identified. The contour of the femoral head is recommended to be used. However, the contour of the femoral head cannot be detected exclusively by computer if it is combined with a bipolar head or a metal cup. We therefore hypothesized that the contour of the outer head of bipolar hemiarthroplasty can be included in the EGS model as well as the femoral head contour. We calculated the time required for the detection of the contour, the precision of analysis and the stem micromotion at 2 years using the two different methods in the same picture set and compared the results. The detection of the bipolar head contour was 10 times faster than that of the femoral head contour. The precision for subsidence was 0.16mm in EGS RSA with the femoral head contour, and 0.15mm with the bipolar head contour (p=0.68). The precisions were comparable and clinically acceptable. There was no significant difference between the results of the 2-year micromotion with the two different methods. We conclude that this new method is applicable to measure stem micromotion of hemi-arthoplasty with EGS RSA and the method facilitates the Radiostereometric analysis.