SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:ca61db63-4646-4f07-9f60-672544cc8fcf"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:ca61db63-4646-4f07-9f60-672544cc8fcf" > Perforated silicon ...

Perforated silicon nerve chips with doped registration electrodes : in vitro performance and in vivo operation

Wallman, L (författare)
Lund University,Lunds universitet,Neuronano Research Center (NRC),Forskargrupper vid Lunds universitet,Lund University Research Groups
Levinsson, A (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Schouenborg, J (författare)
Lund University,Lunds universitet,Neurofysiologi,Forskargrupper vid Lunds universitet,Neuronano Research Center (NRC),Neurophysiology,Lund University Research Groups
visa fler...
Holmberg, H (författare)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Montelius, L (författare)
Lund University,Lunds universitet,Neuronano Research Center (NRC),Forskargrupper vid Lunds universitet,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Lund University Research Groups,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Danielsen, N (författare)
Lund University,Lunds universitet,Neurala gränsytor,Forskargrupper vid Lunds universitet,Neuronano Research Center (NRC),Neural Interfaces,Lund University Research Groups
Laurell, T (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,SEBRA Sepsis and Bacterial Resistance Alliance,Forskargrupper vid Lunds universitet,Masspektrometri,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,CEBMMS PI,Acoustofluidics group,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University Research Groups,Mass Spectrometry,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
1999
1999
Engelska 9 s.
Ingår i: IEEE Transactions on Biomedical Engineering. - 1558-2531. ; 46:9, s. 73-1065
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • An in vitro model was developed for the study of signal transduction between a Cu-wire, miming a neural signal source, and recording electrodes on perforated silicon chips. Phosphorous doped electrodes were used to achieve an all silicon device. The model was used to study signal amplitude as a function of the spatial position, and distance to the signal source. Recordings of the signal crosstalk to neighboring electrodes on the chips were made. It was found that the amplitude decreased by a factor of two at a distance of 50 microns between the electrode surface and the signal source. The chip electrode signal crosstalk was found to be 6 dB using an external reference electrode. Improvements were accomplished with an on chip reference electrode giving a crosstalk suppression of 20 dB. Impedance analysis showed that doped silicon electrodes displayed similar characteristics as Cu-electrodes at frequencies above 3 kHz. Sieve electrodes were implanted in the rat sciatic nerve and following a 10-week nerve regeneration period the dorsal and ventral (L5) roots in the spinal cord were stimulated. Compound action potentials were recorded via the chip. Stimulating the regenerated sciatic nerve via the sieve electrode also induced lower leg muscle contraction activity.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology (hsv//eng)

Nyckelord

Action Potentials
Animals
Biocompatible Materials
Copper
Decerebrate State
Electric Conductivity
Electric Stimulation
Electrodes, Implanted
Equipment Design
Female
Materials Testing
Models, Neurological
Neurons
Pilot Projects
Rats
Rats, Wistar
Sciatic Nerve
Signal Transduction
Silicon
Spinal Cord
Spinal Nerve Roots
Journal Article
Research Support, Non-U.S. Gov't

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy