SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:e1aea5a3-0647-48d9-b29d-7cfafb390734"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:e1aea5a3-0647-48d9-b29d-7cfafb390734" > Glaucoma follow-up ...

  • Heijl, ALund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups,Skåne University Hospital (författare)

Glaucoma follow-up when converting from long to short perimetric threshold tests

  • Artikel/kapitelEngelska2000

Förlag, utgivningsår, omfång ...

  • 2000
  • 5 s.

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:e1aea5a3-0647-48d9-b29d-7cfafb390734
  • https://lup.lub.lu.se/record/e1aea5a3-0647-48d9-b29d-7cfafb390734URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • OBJECTIVES: To study the influence of test length in automated perimetry follow-up of glaucomatous eyes and, particularly, to determine if it is possible to usefully interpret test results obtained using a testing algorithm shorter than that used for baseline testing.METHODS: Automated perimetry findings were retrospectively evaluated in 31 patients with glaucoma for whom multiple Humphrey 30-2 tests were available on the Full Threshold strategy and the SITA Standard strategy.RESULTS: Variability around the mean deviation regression lines was smaller with SITA than with the Full Threshold strategy. Mean deviation values with SITA averaged about 1 dB less severe. Although localized scotomas measured in decibels were deeper on the Full Threshold strategy, number of significantly depressed points on total deviation and pattern deviation probability plot analyses did not differ significantly between the 2 strategies.CONCLUSIONS: The SITA strategy showed test-retest consistency that was at least as good as that of the Full Threshold strategy. The 2 strategies produced similar results when analyzed relative to their respective normal significance limits. Generally, it is appropriate to establish a new baseline when converting from one perimetric algorithm to another. When necessary, however, results may be usefully compared if such comparisons are based on total and pattern deviation probability maps rather than on decibel values.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Bengtsson, BLund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups,Skåne University Hospital(Swepub:lu)ofta-bb0 (författare)
  • Patella, V M (författare)
  • Oftalmologi (Malmö)Forskargrupper vid Lunds universitet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Archives of Ophthalmology118:4, s. 93-4890003-9950

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Heijl, A
Bengtsson, B
Patella, V M
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
Archives of Opht ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy