SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:e2a257f8-ad08-4062-a712-1dbd2ef42f10"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:e2a257f8-ad08-4062-a712-1dbd2ef42f10" > Characterization of...

Characterization of Irreversible Fouling after Ultrafiltration of Thermomechanical Pulp Mill Process Water

Thuvander, Johan (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Zarebska, Agata (författare)
Technical University of Denmark
Helix-Nielsen, Claus (författare)
Technical University of Denmark,University of Maribor
visa fler...
Jönsson, Ann-Sofi (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2018-05-29
2018
Engelska 10 s.
Ingår i: Journal of Wood Chemistry and Technology. - : Informa UK Limited. - 0277-3813 .- 1532-2319. ; 38:3, s. 276-285
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Large volumes of wastewater with dissolved wood components are treated in wastewater treatment plants at thermomechanical pulp mills. It has been shown previously that hemicelluloses in these wastewater streams can be recovered by membrane filtration. A serious obstacle when treating lignocellulose process streams is fouling of the membranes. Fouling not only increases operating costs but also reduces the operating time of the membrane plant. When optimizing the membrane cleaning method, it is important to know which compounds cause the fouling. In this work fouling of an ultrafiltration membrane was studied. The fouling propensity of untreated process water and microfiltrated process water was compared. Fouled membranes were analyzed using scanning electron microscopy and attenuated total reflection Fourier transform infrared spectrometry. Acid hydrolysis of membranes exposed to untreated process water and microfiltration permeate revealed that 508 mg/m2 and 37 mg/m2 of polysaccharides, respectively, remained on the membranes even after alkaline cleaning.

Nyckelord

Fouling
Cleaning
Ultrafiltration
Membrane Autopsy
Hemicelluloses

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy