SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:ef0c9967-c34d-4f17-a5e9-09a1011ecfae"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:ef0c9967-c34d-4f17-a5e9-09a1011ecfae" > The ScanHip total h...

The ScanHip total hip arthroplasty: radiographic assessment of 72 hips after 10 years.

Iwase, Toshiki (författare)
Wingstrand, Inga (författare)
Persson, Björn M (författare)
visa fler...
Kesteris, Uldis (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
Hasegawa, Yukiharu (författare)
Wingstrand, Hans (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2009-07-08
2002
Engelska.
Ingår i: Acta Orthopaedica Scandinavica. - : Medical Journals Sweden AB. - 0001-6470. ; 73:1, s. 54-59
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We analyzed the radiographic and clinical outcome of the ScanHip total hip arthroplasty in 70 patients after 10 years. The Swedish National Hip Register, in which the end-point of the survival analysis is defined as revisions, reported a 10-year survival rate of 94% with the ScanHip, but in the present series 13% of the femoral stems and 29% of the sockets met the criteria for aseptic loosening. Focal osteolysis was found around 8 sockets (11%) and 23 stems (32%) and had occurred significantly oftener around loose sockets, but not around femoral stems. Linear polyethylene wear was significantly increased in loose sockets, but no relationship was noted between polyethylene wear and stem loosening or was there a correlation between clinical symptoms or patients' satisfaction and component loosening. Therefore precise serial long-term radiographic follow-up is the only satisfactory method for detecting aseptic loosening of total hip arthroplasty. It gives the surgeon more detailed information about each case than survival analysis alone.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

Hip : instrumentation
Female
Human
Male
Middle Age
Postoperative Complications : radiography
Prognosis
Prosthesis Design
Prosthesis Failure
Registries
Sweden
Replacement
80 and over
Arthroplasty
Aged
Adult

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy