Sökning: onr:"swepub:oai:lup.lub.lu.se:f821f2e5-849c-44ef-8567-6527ed6ef203" >
Feasibility Study o...
Feasibility Study of Gel Filtration as a Separation Method for Blood Serum Proteins in Combination with PIXE Analysis
-
- Pallon, Jan (författare)
- Lund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
Pakarinen, Pirjo (författare)
-
- Malmqvist, Klas (författare)
- Lund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
visa fler...
-
- Akselsson, Roland (författare)
- Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 1987
- 1987
- Engelska.
-
Ingår i: Biological Trace Element Research. - 1559-0720. ; 12:1, s. 401-409
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The combination between a protein separation technique and the PIXE method has a great potential for large surveys, including thousands of samples, in which multielemental analysis is required. Gel filtration with a Sephadex G-200 gel and a TRIS-acetate buffer was used for separating proteins in human serum. The fractions were doped with an yttrium/vanadium standard and then concentrated and pipeted onto Kimfol™ backing foils. Using the PIXE technique, the distributions of Fe, Cu, Zn, and Se, with respect to molecular size, were found, indicating binding to specific proteins. Sulfur and phosphorus were found to correlate well with the protein content measured by UV-absorption at 280 nm. Further developments and tests on the protein separation technique is required, taking restrictions imposed by the PIXE method into consideration.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
- NATURVETENSKAP -- Fysik -- Subatomär fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Subatomic Physics (hsv//eng)
Nyckelord
- metal-binding proteins
- trace elements
- protein separation
- PIXE
- work environmental health
- human serum
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas