Sökning: onr:"swepub:oai:lup.lub.lu.se:f9575ae4-0a25-4062-a633-47248460e90d" >
Automated Calculati...
Automated Calculation of Infarct Transmurality
-
- Heiberg, Einar (författare)
- Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Engblom, Henrik (författare)
- Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Ugander, Martin (författare)
- Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa fler...
-
- Arheden, Håkan (författare)
- Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- 2007
- 2007
- Engelska.
-
Ingår i: Computers in Cardiology 2007, vols 1 AND 2. - 0276-6574. ; , s. 165-168
- Relaterad länk:
-
http://www.cinc.org/... (free)
-
visa fler...
-
http://dx.doi.org/10...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The aim of this study was to develop all algorithm to automatically calculate infarct transmurality based oil a non dichotomous infarct classification, and to compare with manual delineation. Global transmurality as calculated by the computer algorithm were significantly smaller than the consensus delineation of three observers (p < 0.05). On a regional basis in 6 sectors of each slice the variability of the three observers compared to consensus delineation was 17%, 15%, and 20%. The variability of the automated algorithm was 16%. In conclusion, weighted calculation of transmurality gave smaller global transmurality compared to consensus delineation, but did had the same variability oil a regional basis.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas