PIXE Analysis of Samples of Intermediate Thickness
-
Carlsson, Lars-Eric (författare)
-
- Malmqvist, Klas (författare)
- Lund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
- Johansson, Gerd (författare)
- Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
-
visa fler...
-
- Akselsson, Roland (författare)
- Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 1981
- 1981
- Engelska.
-
Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 181:1-3, s. 179-183
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A procedure for making accurate matrix corrections in PIXE analyses of samples of intermediate thickness has been developed. The transmission of a collimated X-ray beam through different parts of the sample is measured with a Si(Li) detector to determine the thickness and shape of the sample. Experiments have been performed using uniform polymer foils doped with known concentrations of different elements and with thicknesses ranging from 1.5 to 11 mg/cm2. The results from these samples indicate that the accuracy of the correction procedure is better than 5%. The correction procedure has been applied to, e.g., samples obtained in single orifice cascade impactors.
Ämnesord
- NATURVETENSKAP -- Fysik -- Subatomär fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Subatomic Physics (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
Nyckelord
- PIXE
- thickness corrections