Improved performance characteristics of the von Willebrand factor ristocetin cofactor activity assay using a novel automated assay protocol.
-
- Hillarp, Andreas (författare)
- Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
-
Stadler, M (författare)
-
Haderer, C (författare)
-
visa fler...
-
Weinberger, J (författare)
-
Kessler, C M (författare)
-
Römisch, J (författare)
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2010
- 2010
- Engelska.
-
Ingår i: Journal of Thrombosis and Haemostasis. - : Elsevier BV. - 1538-7933 .- 1538-7836. ; 8, s. 2216-2223
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://onlinelibrar...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Summary Background, objectives and methods: An accurate, sensitive and precise assay for reliable determination of the ristocetin cofactor activity of von Willebrand factor (VWF:RCo) in plasma and von Willebrand Factor (VWF)-containing concentrates has been evaluated. The assay is based on a commercially available automated protocol with modifications including a combination of adding additional ristocetin and the use of two calibration curves for the high and low measuring ranges. Results: Addition of extra ristocetin resulted in improved measurement of VWF recoveries from various VWF-containing concentrates that were underestimated using the standard automated protocol. The modifications resulted in improved assay performance over an extended measuring range (2.00 - 0.03 IU/mL). Accuracy was tested using VWF deficiency plasma spiked with 1(st) international standard for VWF concentrate. Seven dilutions, ranging between 1.80 and 0.05 IU/mL, were analyzed and resulted in measured concentrations between 80% and 100% of the assigned potency of the standard. Linearity was determined from the regression plot of the same concentrate dilutions and resulted in a correlation coefficient of 0.998. The repeatability, expressed as coefficient of variation, was 2% in the normal range (0.90 IU/mL) and 8% at the level of 0.05 IU/mL. The corresponding reproducibility results were 2% and 15% at the normal and low measuring ranges, respectively. Conclusions: Analysis of patients with von Willebrand disease indicates that the modified automated BCS((R)) protocol has a superior discrimination power compared with the standard protocol. This is especially true in samples with low VWF, as in patients with type 3 von Willebrand disease.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)