SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:prod.swepub.kib.ki.se:151906419"
 

Sökning: onr:"swepub:oai:prod.swepub.kib.ki.se:151906419" > Developing a video ...

Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study

Khan, AM (författare)
Ahmed, S (författare)
Chowdhury, NH (författare)
visa fler...
Islam, MS (författare)
McCollum, ED (författare)
King, C (författare)
Karolinska Institutet
Shi, T (författare)
Nahar, K (författare)
Simpson, R (författare)
Ahmed, A (författare)
Rahman, MM (författare)
Baqui, AH (författare)
Cunningham, S (författare)
Campbell, H (författare)
, ESPIRE Collaboration (författare)
visa färre...
 (creator_code:org_t)
2022-11-15
2022
Engelska.
Ingår i: BMJ open. - : BMJ. - 2044-6055. ; 12:11, s. e067389-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Manual counting of respiratory rate (RR) in children is challenging for health workers and can result in misdiagnosis of pneumonia. Some novel RR counting devices automate the counting of RR and classification of fast breathing. The absence of an appropriate reference standard to evaluate the performance of these devices is a challenge. If good quality videos could be captured, with RR interpretation from these videos systematically conducted by an expert panel, it could act as a reference standard. This study is designed to develop a video expert panel (VEP) as a reference standard to evaluate RR counting for identifying pneumonia in children.Methods and analysisUsing a cross-sectional design, we will enrol children aged 0–59 months presenting with suspected pneumonia at different levels of health facilities in Dhaka and Sylhet, Bangladesh. We will videorecord a physician/health worker counting RR manually and also using an automated RR counter (Children’s Automated Respiration Monitor) from each child. We will establish a standard operating procedure for capturing quality videos, make a set of reference videos, and train and standardise the VEP members using the reference videos. After that, we will assess the performance of the VEP as a reference standard to evaluate RR counting. We will calculate the mean difference and proportions of agreement within±2 breaths per minute and create Bland-Altman plots with limits of agreement between VEP members.Ethics and disseminationThe study protocol was approved by the National Research Ethics Committee of Bangladesh Medical Research Council, Bangladesh (registration number: 39315022021) and Edinburgh Medical School Research Ethics Committee (EMREC), Edinburgh, UK (REC Reference: 21-EMREC-040). Dissemination of the study findings will be through conference presentations and publications in peer-reviewed scientific journals.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • BMJ open (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy