Sökning: onr:"swepub:oai:prod.swepub.kib.ki.se:1932846" > Measurement of stri...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03661naa a2200445 4500 | |
001 | oai:prod.swepub.kib.ki.se:1932846 | |
003 | SwePub | |
008 | 241004s2000 | |||||||||||000 ||eng| | |
024 | 7 | a http://kipublications.ki.se/Default.aspx?queryparsed=id:19328462 URI |
024 | 7 | a https://doi.org/10.1097/00004647-200002000-000032 DOI |
040 | a (SwePub)ki | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Abi-Dargham, A4 aut |
245 | 1 0 | a Measurement of striatal and extrastriatal dopamine D1 receptor binding potential with [11C]NNC 112 in humans: validation and reproducibility |
264 | c 2016-08-31 | |
264 | 1 | b SAGE Publications,c 2000 |
520 | a To evaluate the postulated role of extrastriatal D1 receptors in human cognition and psychopathology requires an accurate and reliable method for quantification of these receptors in the living human brain. [11C]NNC 112 is a promising novel radiotracer for positron emission tomography imaging of the D1 receptor. The goal of this study was to develop and evaluate methods to derive D1 receptor parameters in striatal and extrastriatal regions of the human brain with [11C]NNC 112. Six healthy volunteers were studied twice. Two methods of analysis (kinetic and graphical) were applied to 12 regions (neocortical, limbic, and subcortical regions) to derive four outcome measures: total distribution volume, distribution volume ratio, binding potential (BP), and specific-to-nonspecific equilibrium partition coefficient ( k3/ k4). Both kinetic and graphic analyses provided BP and k3/ k4 values in good agreement with the known distribution of D1 receptors (striatum > limbic regions = neocortical regions > thalamus). The identifiability of outcome measures derived by kinetic analysis was excellent. Time-stability analysis indicated that 90 minutes of data collection generated stable outcome measures. Derivation of BP and k3/ k4 by kinetic analysis was highly reliable, with intraclass correlation coefficients (ICCs) of 0.90 ± 0.06 (mean ± SD of 12 regions) and 0.84 ± 0.11, respectively. The reliability of these parameters derived by graphical analysis was lower, with ICCs of 0.72 ± 0.17 and 0.58 ± 0.21, respectively. Noise analysis revealed a noise-dependent bias in the graphical but not the kinetic analysis. In conclusion, kinetic analysis of [11C]NNC 112 uptake provides an appropriate method with which to derive D1 receptor parameters in regions with both high (striatal) and low (extrastriatal) D1 receptor density. | |
700 | 1 | a Martinez, D4 aut |
700 | 1 | a Mawlawi, O4 aut |
700 | 1 | a Simpson, N4 aut |
700 | 1 | a Hwang, DR4 aut |
700 | 1 | a Slifstein, M4 aut |
700 | 1 | a Anjilvel, S4 aut |
700 | 1 | a Pidcock, J4 aut |
700 | 1 | a Guo, NN4 aut |
700 | 1 | a Lombardo, I4 aut |
700 | 1 | a Mann, JJ4 aut |
700 | 1 | a Van Heertum, R4 aut |
700 | 1 | a Foged, C4 aut |
700 | 1 | a Halldin, Cu Karolinska Institutet4 aut |
700 | 1 | a Laruelle, M4 aut |
710 | 2 | a Karolinska Institutet4 org |
773 | 0 | t Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolismd : SAGE Publicationsg 20:2, s. 225-243q 20:2<225-243x 0271-678X |
773 | 0 | t Journal of Cerebral Blood Flow & Metabolismd : SAGE Publicationsg 20:2, s. 225-243q 20:2<225-243x 1559-7016 |
856 | 4 | u https://journals.sagepub.com/doi/pdf/10.1097/00004647-200002000-00003 |
856 | 4 8 | u http://kipublications.ki.se/Default.aspx?queryparsed=id:1932846 |
856 | 4 8 | u https://doi.org/10.1097/00004647-200002000-00003 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy