Sökning: onr:"swepub:oai:research.chalmers.se:08b60a61-7bf3-4812-8398-6b3cb54c6cbf" >
Modeling and Experi...
Modeling and Experimental Verification of Grid Interaction of a DFIG Wind Turbine
-
- Petersson, Andreas, 1974 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology,Department of Energy and Environment, Chalmers University of Technology, Goteborg, Sweden
-
- Thiringer, Torbjörn, 1966 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology,Department of Energy and Environment, Chalmers University of Technology, Goteborg, Sweden,NACHI Czech, Louny, Czech Republic
-
- Harnefors, Lennart, 1968 (författare)
- Mälardalens universitet,ABB Power Technologies AB, Ludvika, Sweden
-
visa fler...
-
- Petru, Tomas, 1974 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa färre...
-
(creator_code:org_t)
- Chalmers Univ Technol, Dept Energy & Environm, SE-41296 Gothenburg, Sweden. Malardalen Univ, Dept Comp Sci & Elect, SE-72123 Vasteras, Sweden. NACHI Czech, Louny, Czech Republic. IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2005
- 2005
- Engelska.
-
Ingår i: IEEE Transactions on Energy Conversion. - Chalmers Univ Technol, Dept Energy & Environm, SE-41296 Gothenburg, Sweden. Malardalen Univ, Dept Comp Sci & Elect, SE-72123 Vasteras, Sweden. NACHI Czech, Louny, Czech Republic. : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 1558-0059 .- 0885-8969. ; 20:4, s. 878- 886
- Relaterad länk:
-
https://research.cha...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- The response of the doubly fed induction generator (DFIG) wind turbine system to grid disturbances is simulated and verified experimentally. The results are compared to the response that a fixed-speed wind turbine would have given. A voltage sag to 80% (80% remaining voltage) is handled very well, which is not the case for a fixed-speed wind turbine. A second-order model for prediction of the response of DFIG wind turbines is derived, and its simulated performance is successfully verified experimentally. The power quality impact by the DFIG wind turbine system is measured and evaluated. Steady-state impact, such as flicker emission, reactive power, and harmonic emission, is measured and analyzed. It is found that the flicker emission is very low, the reactive power is close to zero in the whole operating range, and the current THD is always lower than 5%.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
Nyckelord
- power quality
- voltage sag
- Doubly fed induction generator
- wind turbine
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas