SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:0df5043e-3b7f-4c65-b9ac-9d219e9ab3ce"
 

Sökning: onr:"swepub:oai:research.chalmers.se:0df5043e-3b7f-4c65-b9ac-9d219e9ab3ce" > Application of the ...

Application of the ESHO-QA guidelines for determining the performance of the LCA superficial hyperthermia heating system

Carrapiço-Seabra, Carolina (författare)
Erasmus MC Cancer Institute
de Lazzari, Mattia, 1996 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Ameziane, Abdelali (författare)
Erasmus MC Cancer Institute
visa fler...
Van Rhoon, G. C. (författare)
Erasmus MC Cancer Institute,Technische Universiteit Delft,Delft University of Technology (TU Delft)
Dobsicek Trefna, Hana, 1979 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Curto, S. (författare)
Erasmus MC Cancer Institute
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: International Journal of Hyperthermia. - 0265-6736 .- 1464-5157. ; 40:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: This study aimed to assess the quality of the lucite cone applicator (LCA), the standard applicator for superficial hyperthermia at the Erasmus MC Cancer Institute, using the most recent quality assurance guidelines, thus verifying their feasibility. Materials and methods: The assessment was conducted on each of the six LCAs available for clinical treatments. The temperature distribution was evaluated using an infrared camera across different layers of a fat-muscle mimicking phantom. The maximum temperature increase, thermal effective penetration depth (TEPD), and thermal effective field size (TEFS) were used as quality metrics. The experimental results were validated through comparison with simulated results, using a canonical phantom model and a realistic phantom model segmented from CT imaging. Results: A maximum temperature increase above 6 °C at 2 cm depth in the fat-muscle phantom for all the experiments was found. A mean negative difference between simulated and experimental data was of 1.3 °C when using the canonical phantom model. This value decreased to a mean negative difference of 0.4 °C when using the realistic model. Simulated and measured TEPD showed good agreement for both in silico scenarios, while discrepancies were present for TEFS. Conclusions: The LCAs passed all QA guidelines requirements for superficial hyperthermia delivery when used singularly or in an array configuration. A further characterization of parameters such as antenna efficiency and heat transfer coefficients would be beneficial for translating experimental results to simulated values. Implementing the QA guidelines was time-consuming and demanding, requiring careful preparation and correct setup of antenna elements.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

LCA
Hyperthermia
superficial applicators
quality assurance (QA)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy