SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:1c357ba4-58ff-452d-a841-8a3eaedb5a61"
 

Sökning: onr:"swepub:oai:research.chalmers.se:1c357ba4-58ff-452d-a841-8a3eaedb5a61" > Analysis of operati...

Analysis of operational data from a district cooling system and its connected buildings

Jangsten, Maria, 1989 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Lindholm, Torbjörn, 1965 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Dalenbäck, Jan-Olof, 1954 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
Elsevier BV, 2020
2020
Engelska.
Ingår i: Energy. - : Elsevier BV. - 0360-5442. ; 203
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • District cooling systems are likely to become more common as the cooling demands in cities increase. Their performance is often challenged by low temperature differences between the supply and return water, called low delta-T. Few previous studies have investigated low delta-Ts in district cooling systems with heat exchangers separating the distribution system and the connected buildings, which therefore is the objective of this study. The study is based on an analysis of operational data from both district cooling provider and 37 of the connected buildings chilled water systems, collected from the energy transfer stations during spring and summer of 2018. The design delta-T in the district cooling system is 10 °C, while the actual delta-T varies between 6 and 8 °C. The study shows the main causes to the low delta-T are the following: operation in the saturation zone; too low building chilled water return temperature; too low temperature approach of the heat exchanger's supply streams and non-optimized supply temperatures in the buildings. Potential solutions to resolve the low delta-T include adjusting the supply temperature setpoint on the secondary side; restricting the flow on the primary side; providing economic incentives for the district cooling customers and ensuring compliance with the design guidelines.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Temperature approach
Building chilled water system
Low delta-T
Heat exchanger
Energy transfer station
District cooling

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Energy (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jangsten, Maria, ...
Lindholm, Torbjö ...
Dalenbäck, Jan-O ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Naturresurstekni ...
och Energisystem
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
Artiklar i publikationen
Energy
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy