Cold-electron bolometer integrated with a unilateral finline

Otto, Ernst, 1971 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Tarasov, Mikhail, 1954 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Grimes, P. K. (författare)
University Of Oxford
visa fler...
Kuzmin, Leonid, 1946 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Yassin, G. (författare)
University Of Oxford
visa färre...
 (creator_code:org_t)
ISBN 9781617823626
2010
2010
Engelska.
Ingår i: 21st International Symposium on Space Terahertz Technology 2010, ISSTT 2010; Oxford; United Kingdom; 23 March 2010 through 25 March 2010. - 9781617823626 ; , s. 238-243
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The Cold-Electron Bolometer (CEB) is a very sensitive millimetre-wave detector which is easy to integrate with planar circuits. CEB detectors have other important features such as high saturation power and very fast response. We have designed, fabricated and tested CEB detectors integrated across the slot of a unilateral finline on silicon substrate. Bolometers were fabricated using e-beam directwrite trilayer technology. The CEB performance was tested in a He3 sorption cryostat HELIOX-AC-V at a bath temperature of 280 mK. To reduce the background power radiation overheating the optical window in the cryostat was equipped with two low-pass filters with cut-off frequency 33 cm-1 and 100 cm-1 and 2 neutral density filters with 10 db attenuation each. DC IV curves were measured in a current bias mode, optical response was measured by irradiating samples with a microwave signal from IMPATT diode at 110 GHz modulated at 127 Hz. These tests were conducted by coupling power directly into the finline chip. The signal response was measured using a lock-in amplifier. The bolometer dark electrical noise equivalent power is estimated to be about NEP=5·10-16 W/Hz1/2.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Neutral density filters
Cold electron bolometers
Trilayer technology
Cryostats
Silicon substrates
Microwave signals
Bath temperatures
Infrared detectors
IMPATT diodes
Lock-in amplifier
Detectors
Important features
Bolometers

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy