Sökning: onr:"swepub:oai:research.chalmers.se:2860f9c6-0256-4a42-814d-3cb7fc1ad840" >
Gamma-Radiolytic St...
Gamma-Radiolytic Stability of Solvents Containing C5-BPP (2,6-Bis(5-(2,2-dimethylpropyl)-1H-pyrazol-3-yl)pyridine) for Actinide(III)/Lanthanide(III) Separation
-
- Wilden, A. (författare)
- Forschungszentrum Jülich GmbH
-
- Modolo, G. (författare)
- Forschungszentrum Jülich GmbH
-
- Hupert, M. (författare)
- Forschungszentrum Jülich GmbH
-
visa fler...
-
- Santiago-Schubel, B. (författare)
- Forschungszentrum Jülich GmbH
-
- Löfström Engdahl, Elin, 1983 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Halleröd, Jenny, 1987 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Ekberg, Christian, 1967 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Mincher, B. J. (författare)
- Idaho National Laboratory
-
- Mezyk, S. P. (författare)
- The California State University, United States
-
visa färre...
-
(creator_code:org_t)
- 2015-11-05
- 2016
- Engelska.
-
Ingår i: Solvent Extraction and Ion Exchange. - : Informa UK Limited. - 0736-6299 .- 1532-2262. ; 34:1, s. 1-12
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://doi.org/10.1...
-
https://research.cha...
-
visa färre...
Abstract
Ämnesord
Stäng
- The stability of solvents containing the C5-BPP (2,6-Bis(5-(2,2-dimethylpropyl)-1H-pyrazol-3-yl)pyridine) extractant against gamma-irradiation up to 330 kGy adsorbed dose was evaluated using HPLC mass spectrometric and solvent extraction methods. The main radiolysis products were identified using high-resolution mass spectrometry. Quantitative analysis of the residual C5-BPP concentration in irradiated samples was accomplished by a specifically developed MRM (Multiple Reaction Monitoring) method. A mixture of C5-BPP with 2-bromohexanoic acid in kerosene and 1-octanol, which had been used in an actinide(III)/lanthanide(III) separation process demonstration test, was also studied for its radiolytic stability and a remarkable protective effect of the presence of nitric acid during irradiation was found.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Kemiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Chemical Engineering (hsv//eng)
Nyckelord
- radiolysis
- mass-spectrometry
- multiple reaction monitoring
- C5-BPP
- high resolution mass spectrometry