Sökning: onr:"swepub:oai:research.chalmers.se:31329c0e-5c8b-400e-84d1-0bbdac852574" > Elevation angle ali...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03255naa a2200433 4500 | |
001 | oai:research.chalmers.se:31329c0e-5c8b-400e-84d1-0bbdac852574 | |
003 | SwePub | |
008 | 171006s2012 | |||||||||||000 ||eng| | |
024 | 7 | a https://research.chalmers.se/publication/1690042 URI |
024 | 7 | a https://doi.org/10.1063/1.47373872 DOI |
040 | a (SwePub)cth | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a art2 swepub-publicationtype |
072 | 7 | a ref2 swepub-contenttype |
100 | 1 | a Moseev, D.u Max Planck Gesellschaft zur Förderung der Wissenschaften e.V. (MPG),Max Planck Society for the Advancement of Science (MPG)4 aut |
245 | 1 0 | a Elevation angle alignment of quasi optical receiver mirrors of collective Thomson scattering diagnostic by sawtooth measurements |
264 | 1 | b AIP Publishing,c 2012 |
520 | a Localized measurements of the fast ion velocity distribution function and the plasma composition measurements are of significant interest for the fusion community. Collective Thomson scattering (CTS) diagnostics allow such measurements with spatial and temporal resolution. Localized measurements require a good alignment of the optical path in the transmission line. Monitoring the alignment during the experiment greatly benefits the confidence in the CTS measurements. An in situ technique for the assessment of the elevation angle alignment of the receiver is developed. Using the CTS diagnostic on TEXTOR without a source of probing radiation in discharges with sawtooth oscillations, an elevation angle misalignment of 0.9 degrees was found with an accuracy of 0.25 degrees. | |
650 | 7 | a NATURVETENSKAPx Fysik0 (SwePub)1032 hsv//swe |
650 | 7 | a NATURAL SCIENCESx Physical Sciences0 (SwePub)1032 hsv//eng |
653 | a radiation | |
653 | a ion temperature | |
700 | 1 | a Meo, F.u Danmarks Tekniske Universitet,Technical University of Denmark4 aut |
700 | 1 | a Korsholm, S. B.u Danmarks Tekniske Universitet,Technical University of Denmark4 aut |
700 | 1 | a Bindslev, H.u Århus Universitet,Aarhus University4 aut |
700 | 1 | a Furtula, Vedran,d 1981u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)furtula |
700 | 1 | a Kantor, M.u Forschungszentrum Jülich GmbH,Russian Academy of Sciences4 aut |
700 | 1 | a Leipold, F.u Danmarks Tekniske Universitet,Technical University of Denmark4 aut |
700 | 1 | a Michelsen, P. K.u Danmarks Tekniske Universitet,Technical University of Denmark4 aut |
700 | 1 | a Nielsen, S. K.u Danmarks Tekniske Universitet,Technical University of Denmark4 aut |
700 | 1 | a Salewski, M.u Danmarks Tekniske Universitet,Technical University of Denmark4 aut |
700 | 1 | a Stejner, M.u Danmarks Tekniske Universitet,Technical University of Denmark4 aut |
710 | 2 | a Max Planck Gesellschaft zur Förderung der Wissenschaften e.V. (MPG)b Danmarks Tekniske Universitet4 org |
773 | 0 | t Review of Scientific Instrumentsd : AIP Publishingg 83:10q 83:10x 1089-7623x 0034-6748 |
856 | 4 | u http://dx.doi.org/10.1063/1.4737387y FULLTEXT |
856 | 4 | u https://backend.orbit.dtu.dk/ws/files/10444553/Elevation_angle_alignment.pdf |
856 | 4 8 | u https://research.chalmers.se/publication/169004 |
856 | 4 8 | u https://doi.org/10.1063/1.4737387 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy