Sökning: onr:"swepub:oai:research.chalmers.se:3fcf3e4e-3b20-49c9-b16c-4eaef27e0e90" >
Combining direct gr...
Combining direct ground cooling with ground-source heat pumps and district heating: Energy and economic analysis
-
- Arghand, Taha, 1982 (författare)
- Chalmers University of Technology
-
- Javed, Saqib, 1978 (författare)
- Lund University,Lunds universitet,Avdelningen för Installations- och klimatiseringslära,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Building Services,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
-
- Dalenbäck, Jan-Olof, 1954 (författare)
- Chalmers University of Technology
-
(creator_code:org_t)
- Elsevier BV, 2023
- 2023
- Engelska.
-
Ingår i: Energy. - : Elsevier BV. - 0360-5442 .- 1873-6785. ; 270
- Relaterad länk:
-
https://research.cha... (primary) (free)
-
visa fler...
-
http://dx.doi.org/10... (free)
-
https://research.cha...
-
https://doi.org/10.1...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- Direct ground cooling (DGC) is a method used in cold climates to provide cooling to buildings without the use of any mechanical refrigeration. When DGC is utilized for providing cooling, ground-source heat pumps (GSHPs) and district heating (DH) are the two commonly used technologies for providing heating to the buildings. This article investigates the coupling of DGC with GSHPs and DH in terms of purchased energy and lifecycle costs. An office building equipped with active chilled beams for cooling and radiators for heating is used as a reference. Six cases based on different combinations of building envelope characteristics and thus different building heating and cooling loads are considered. The results show that using DGC-DH significantly reduces the amount of purchased electricity. However, the total energy cost is lower when DGC-GSHP is used. In addition, the DGC-GSHP can be more viable when the ground loads are well balanced. Investment costs, including borehole installation and equipment costs, are lower for the DGC-DH in the majority of the investigated cases. The lifecycle cost is lower for the DGC-DH in most of the investigated cases due to lower equipment costs.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Naturresursteknik -- Energisystem (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Environmental Engineering -- Energy Systems (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Building Technologies (hsv//eng)
Nyckelord
- Ground-source heat pump (GSHP)
- High-temperature cooling
- Lifecycle cost (LCC)
- Energy efficiency
- District heating
- Direct ground cooling
- Direct ground cooling
- District heating
- Energy efficiency
- Ground-source heat pump (GSHP)
- High-temperature cooling
- Lifecycle cost (LCC)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
-
Energy
(Sök värdpublikationen i LIBRIS)
Till lärosätets databas