Sökning: onr:"swepub:oai:research.chalmers.se:414e7b29-f595-460c-aa2d-93af591a07fb" >
Characteristics of ...
Characteristics of the Lateral Particle Distribution in Circulating Fluidized Red Boilers
-
- Zhang, Wennan, 1962 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Johnsson, Filip, 1960 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Leckner, Bo G, 1936 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
(creator_code:org_t)
- 1993
- 1993
- Engelska.
-
Ingår i: Proc of the 4th International Conference on Circulating Fluidized Beds. ; , s. 266-273
- Relaterad länk:
-
https://research.cha...
Abstract
Ämnesord
Stäng
- The local time-averaged solids volume fraction was measured in the 12MW~1 Circulating Ruidized Bed (CFR) boiler at Chalmers University of Technology. It was found that the corelwall-layer structure of the flow pattern observed in small-scale beds also characterizes large-scale CFR boilers. The local solids volume fractions close to the wall and in the core region of the furnace were found to be directly proportional to the cross-sectional average solids volume fraetjon, c, as ohtained from pressure rneasurements. If the shape of the membrane-tube wall is taken into account, the relationship for the solids fraction close to the wall (related to a plane wall) is c~=3.6c, which is similar to that reported in literature for plain walls.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
Nyckelord
- Boiler
- Lateral particle distribution
- Fluid dynamics
- Circulating fluidized bed
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)