Sökning: onr:"swepub:oai:research.chalmers.se:5c79d294-3c51-41ac-8a44-a0b257209732" >
Two-dimensional flo...
Two-dimensional flow nanometry of biological nanoparticles for accurate determination of their size and emission intensity
-
- Block, Stephan, 1978 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Johansson Fast, Björn, 1986 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Lundgren, Anders, 1978 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa fler...
-
- Zhdanov, Vladimir, 1952 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Höök, Fredrik, 1966 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa färre...
-
(creator_code:org_t)
- 2016-09-23
- 2016
- Engelska.
-
Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723 .- 2041-1723. ; 7, s. art no 12956 -
- Relaterad länk:
-
http://publications.... (primary) (free)
-
visa fler...
-
https://www.nature.c...
-
https://research.cha...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Biological nanoparticles (BNPs) are of high interest due to their key role in various biological processes and use as biomarkers. BNP size and composition are decisive for their functions, but simultaneous determination of both properties with high accuracy remains challenging. Optical microscopy allows precise determination of fluorescence/scattering intensity, but not the size of individual BNPs. The latter is better determined by tracking their random motion in bulk, but the limited illumination volume for tracking this motion impedes reliable intensity determination. Here, we show that by attaching BNPs to a supported lipid bilayer, subjecting them to hydrodynamic flows and tracking their motion via surface-sensitive optical imaging enable determination of their diffusion coefficients and flow-induced drifts, from which accurate quantification of both BNP size and emission intensity can be made. For vesicles, the accuracy of this approach is demonstrated by resolving the expected radius-squared dependence of their fluorescence intensity for radii down to 15 nm.
Ämnesord
- NATURVETENSKAP -- Fysik -- Den kondenserade materiens fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Condensed Matter Physics (hsv//eng)
Nyckelord
- tethered vesicle
- hydrodynamic-forces
- single-particle tracking
- targeted drug-delivery
- lipid-bilayers
- vesicles
- endocytosis
- cytometry
- extracellular
- microparticles
- virus
- entry
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas