SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:77f58902-37af-4ac1-94b2-e3e937550888"
 

Sökning: onr:"swepub:oai:research.chalmers.se:77f58902-37af-4ac1-94b2-e3e937550888" > Electro-acoustic pe...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003196naa a2200373 4500
001oai:research.chalmers.se:77f58902-37af-4ac1-94b2-e3e937550888
003SwePub
008171007s2015 | |||||||||||000 ||eng|
024a https://doi.org/10.3109/14992027.2014.9805212 DOI
024a https://research.chalmers.se/publication/2168082 URI
040 a (SwePub)cth
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Fredén Jansson, Karl-Johan,d 1988u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)karljohf
2451 0a Electro-acoustic performance of the new bone vibrator Radioear B81: A comparison with the conventional Radioear B71
264 c 2014-12-18
264 1b Informa UK Limited,c 2015
520 a Objective: The objective is to evaluate the electro-acoustic performance of a new audiometric bone vibrator, the B81 from Radioear Corporation, USA. Comparison will be made with the widely used B71 which has well-known limitations at low frequencies. Design: The B81 is based on the balanced electromagnetic separation transducer (BEST) principle where static forces are counterbalanced so that nonlinear distortion forces are reduced and maximum hearing levels can be increased. Study sample: Maximum hearing level, total harmonic distortion (THD), frequency response, and electrical impedance were measured for six devices of each bone vibrator type on an artificial mastoid. Results: It was found that B81 reaches 10.7-22.0 dB higher maximum (@ THD. 6% or V-in. 6 V-RMS) hearing levels than B71 for frequencies below 1500 Hz, and had significantly lower THD up to 1000 Hz. There was no statistically significant difference between their frequency response, except a deviation at the mid frequencies (alpha = 0.01) where B81 was more efficient and the electrical impedances were practically the same. Conclusions: In general, B81 had an improved electro-acoustic performance compared to B71 and is compatible with same audiometers. In particular, B81 allows for sensorineural hearing loss to be measured at considerably higher hearing levels than with B71 below 1500 Hz.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Oto-rhino-laryngologi0 (SwePub)302182 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Otorhinolaryngology0 (SwePub)302182 hsv//eng
653 a Audiology
653 a electromagnetic transducer
653 a electro-acoustics
653 a bone conduction
700a Håkansson, Bo,d 1953u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)boh
700a Johannsen, L.4 aut
700a Tengstrand, Tomasu Göteborgs universitet,University of Gothenburg4 aut
710a Chalmers tekniska högskolab Göteborgs universitet4 org
773t International Journal of Audiologyd : Informa UK Limitedg 54:5, s. 334-340q 54:5<334-340x 1499-2027x 1708-8186
856u http://dx.doi.org/10.3109/14992027.2014.980521y FULLTEXT
8564 8u https://doi.org/10.3109/14992027.2014.980521
8564 8u https://research.chalmers.se/publication/216808

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy