Sökning: onr:"swepub:oai:research.chalmers.se:8238ca2a-dcd8-42f0-adfa-5303e4ba473a" >
Bond of naturally c...
Bond of naturally corroded, plain reinforcing bars in concrete
-
- Robuschi, Samanta, 1991 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Sumearll, Jakob (författare)
- University of Washington
-
- Fernandez, Ignasi, 1984 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa fler...
-
- Lundgren, Karin, 1968 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa färre...
-
(creator_code:org_t)
- 2020-05-23
- 2021
- Engelska.
-
Ingår i: Structure and Infrastructure Engineering. - : Informa UK Limited. - 1573-2479 .- 1744-8980. ; 17:6, s. 792-808
- Relaterad länk:
-
https://research.cha... (primary) (free)
-
visa fler...
-
https://www.tandfonl...
-
https://doi.org/10.1...
-
https://research.cha...
-
visa färre...
Abstract
Ämnesord
Stäng
- In the past, reinforced concrete structures were built utilising plain reinforcement bars. Currently, this construction method is seldom considered by codes and research; however, many heritage structures are still standing and in need of proper assessment. In particular, there is a lack of knowledge on the effect of corrosion on the bond between concrete and plain reinforcement bars. To address this gap, pullout tests were performed on reinforced concrete specimens sourced from a decommissioned bridge originally constructed in 1935. The specimens were naturally corroded, as the use of accelerated corrosion techniques in structural tests is still debated. A total of 156 pullout tests were conducted on specimens with varying thicknesses. The pullout force, active and passive slip, and corrosion levels were measured. The effect of corrosion on the bond strength, and the amount of visible damage owing to the presence of corrosion products, were influenced by the casting position of the reinforcing bars. The presence of stirrups influenced the post-peak behaviour, increased the residual bond strength, and helped maintain the bond strength in the presence of cracks and spalling damage. Additionally, current code provisions were found to provide conservative values for the peak bond stress of plain reinforcing bars.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Building Technologies (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Kemiteknik -- Korrosionsteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Chemical Engineering -- Corrosion Engineering (hsv//eng)
Nyckelord
- bond strength
- Reinforced concrete
- existing structures
- plain reinforcing bars
- natural corrosion
- pullout tests
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas