SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:a33fe58f-592a-47a4-8110-7edfebdea667"
 

Sökning: onr:"swepub:oai:research.chalmers.se:a33fe58f-592a-47a4-8110-7edfebdea667" > Assessment of the m...

Assessment of the mechanical behaviour of reinforcement bars with localised pitting corrosion by Digital Image Correlation

Chen, Teresa E, 1988 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Gil Berrocal, Carlos, 1986 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Fernandez, Ignasi, 1984 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Löfgren, Ingemar, 1972 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Lundgren, Karin, 1968 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
Elsevier BV, 2020
2020
Engelska.
Ingår i: Engineering Structures. - : Elsevier BV. - 1873-7323 .- 0141-0296. ; 219
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Corrosion of reinforcement in concrete impairs the mechanical behaviour of rebars by decreasing their strength and deformation capacity. In this study, uniaxial tensile tests were carried out on 61 rebars taken from 22 pre- and un- cracked reinforced concrete beams subjected to drying and wetting cycles in chloride solution for over three years. A 3D-scanning technique was used to characterise the maximum local corrosion level, μmax, and different pit shape parameters. Digital Image Correlation (DIC) was used to capture the displacement field of the test bars; the engineering strain was measured through the virtual extensometers created in the DIC post-processing software. The proof and ultimate forces showed linear decreasing trends of μmax, while the proof and ultimate strengths (based on the minimum residual cross-sectional area) were not obviously affected by corrosion. The ultimate strain of corroded bars depended on the gauge length due to strain localisation in the pit. Thus, it was emphasised that the ultimate strain may be overestimated if measured based on a short gauge across the pit. It was also observed that when μmax exceeded a critical local corrosion level (μcrit depending on the ratio between the yield and ultimate strengths of the steel), the region outside the pit did not develop yielding. A lower bound of ultimate strain was further derived as a function of the mechanical parameters of uncorroded steel and maximum local corrosion level. This provided a good comparison with the experimental results. Ultimately, a hypothesis for time-dependent assessment of strain capacity is proposed, considering the evolution of corrosion morphology over time.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Infrastrukturteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Infrastructure Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Metallurgi och metalliska material (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Metallurgy and Metallic Materials (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Kemiteknik -- Korrosionsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering -- Corrosion Engineering (hsv//eng)

Nyckelord

3D-scanning
Pitting corrosion
Mechanical properties
Strain measurement
Digital Image Correlation

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy