Validation of optical remote sensing measurement strategies applied to industrial gas emissions

Rivera, Claudia, 1976 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
García, Jose Antonio (författare)
Universidad del Pais Vasco / Euskal Herriko Unibertsitatea,University of the Basque Country (UPV/EHU)
Galle, Bo, 1952 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Alonso, Lucio (författare)
Universidad del Pais Vasco / Euskal Herriko Unibertsitatea,University of the Basque Country (UPV/EHU)
Zhang, Yan, 1976 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Johansson, Mattias Erik, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Matabuena, Mónica (författare)
Universidad del Pais Vasco / Euskal Herriko Unibertsitatea,University of the Basque Country (UPV/EHU)
Gangoiti, Gotzon (författare)
Universidad del Pais Vasco / Euskal Herriko Unibertsitatea,University of the Basque Country (UPV/EHU)
visa färre...
 (creator_code:org_t)
2010-03-29
2009
Engelska.
Ingår i: International Journal of Remote Sensing. - : Informa UK Limited. - 1366-5901 .- 0143-1161. ; 30:12, s. 3191-3204
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In May 2004 a field-campaign was conducted at a power plant in Spain, aiming at validating the use of a miniaturized, fibre-optic, ultraviolet, differential optical absorption spectrometer (mini-DOAS) instrument for sulphur dioxide flux (SO2) quantification. Emissions were determined by integrating the total number of molecules in a vertical cross-section of the gas plume, and multiplying them by the wind component at plume height. Calculated wind data was compared with balloon soundings. Plume height, computed from a tomographic reconstruction of the plume was compared with stereo-photogrammetric methods and a plume rise model. Finally, SO2 fluxes were compared to emissions reported by the power station. Although the meteorological conditions during the field-campaign were adverse, with large fluctuations in wind-speed and wind-direction, the optical measurements performed proved to be practically feasible and compared well with the techniques used for the validation. SO2 fluxes derived by mini-DOAS were within 7% of the ones reported by the power station.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Annan geovetenskap och miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Other Earth and Related Environmental Sciences (hsv//eng)

Nyckelord

mini-DOAS
sulphur dioxide
industrial
monitoring
scanners

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy