SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:bc915a6f-291e-4cb3-854d-9602c436f9be"
 

Sökning: onr:"swepub:oai:research.chalmers.se:bc915a6f-291e-4cb3-854d-9602c436f9be" > Benchmarking the St...

Benchmarking the Stability of Oxygen Evolution Reaction Catalysts: The Importance of Monitoring Mass Losses

Frydendal, Rasmus (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Paoli, Elisa A. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Knudsen, Brian P. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
visa fler...
Wickman, Björn, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Malacrida, Paolo (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Stephens, Ifan E. L. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Chorkendorff, Ib (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
visa färre...
 (creator_code:org_t)
2014-10-05
2014
Engelska.
Ingår i: ChemElectroChem. - : Wiley. - 2196-0216. ; 1:12, s. 2075-2081
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Because of the rising need for energy storage, potentially facilitatedby electrolyzers, improvements to the catalysis of theoxygen evolution reaction (OER) become increasingly relevant.Standardized protocols have been developed for determiningcritical figures of merit, such as the electrochemical surfacearea, mass activity and specific activity. Even so, when new andmore active catalysts are reported, the catalyst stability tendsto play a minor role. In this work, we monitor corrosion onRuO2 and MnOx by combining the electrochemical quartz crystalmicrobalance (EQCM) with inductively coupled plasma massspectrometry (ICP–MS). We show that a meaningful estimationof the stability cannot be achieved based on purely electrochemicaltests. On the catalysts tested, the anodic dissolutioncurrent was four orders of magnitude lower than the total current.We propose that even if long-term testing cannot be replaced,a useful evaluation of the stability can be achievedwith short-term tests by using EQCM or ICP–MS.

Ämnesord

NATURVETENSKAP  -- Kemi -- Fysikalisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Physical Chemistry (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy